Ready For Sale
Secondhand EIZO RadiForce RX250 Medical Monitor
Price: USD$ 2.500,00 Approx: 110.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 09.12.2025
EIZO RadiForce RX250 Medical Monitor Analysis Report
Device Identification
The product examined in the visuals is a high-quality LCD monitor suitable for vertical (portrait) or horizontal (landscape) use, intended for professional medical imaging. The device is an industrial-grade display designed to meet diagnostic imaging standards, especially in the healthcare sector, featuring a special stand and a robust casing structure.
Brand and Model
As a result of detailed examination of the product, brand and model information has been definitively identified. The information on the device’s rear label and its original box perfectly matches.
- Brand: EIZO
- Model: RadiForce RX250
- Product Class: 54.0 cm (21.3 inch) Class Color LCD Monitor
The inscription “RadiForce RX250” is clearly legible on the device’s labels. The EIZO brand logo is prominent on the monitor’s bottom right bezel, on the back, and on the box.
Authenticity and Box Matching
The product is displayed with its original factory box and protective styrofoam inserts. The serial number on the device’s rear label was compared with the serial number on the box label, and a perfect match was found. This proves that the product is 100% original and has been stored with its own box.
- Workmanship Quality: The inscription “Made in Japan” is present on the device label. The casing quality reflects EIZO’s typical high-standard industrial design.
Areas of Use
The EIZO RadiForce RX250 is a diagnostic monitor specifically manufactured for the medical sector. It is not a standard home or office monitor. Its primary areas of use include:
- Reviewing X-ray, MRI, and CT scans by radiology specialists.
- PACS (Picture Archiving and Communication Systems) workstations.
- Clinical imaging procedures requiring high contrast and clarity.
- Displaying both black-and-white (grayscale) and color medical images with accurate calibration.
Label and Identification Information
The technical identification information found on the device’s rear panel and the box label is as follows:
- Serial Number (S/N): 38154128
- Part Number (P/N): 0FTD2137D2+
- Production Date: 2018-12-26 (December 26, 2018)
- Revision: Rev C
- Ref Code (On Box): RX250EDBK
- Color: BLACK
- Power Input: AC 100-240V, 50/60Hz, 0.80A-0.35A
General Condition and Cosmetic Examination
The product appears to be in very good and clean cosmetic condition. Being photographed within its original packaging suggests that the device has been carefully stored or lightly used.
- Screen Surface: It has a matte panel structure. No significant deep scratches, cracks, or impact marks were observed on the screen, apart from natural reflections caused by light.
- Casing: No significant deformation, discoloration, or wear was detected on the dark grey/black colored casing. The corners and bezels are in clean condition.
- Stand/Base: The product is on its original and ergonomic stand. There is a white cable management clip on the back of the stand, which appears sturdy. The stand has a mechanical structure that supports up-down height adjustment and pivot (vertical rotation) features.
Mechanical and Electronic Component Analysis
Mechanical and electronic findings based on visual inspection are as follows:
- Front Control Panel: Touch or soft-touch control buttons are present on the right bezel of the screen. Button icons (Power, Menu, etc.) are not faded.
- Integrated Sensor: A calibration sensor slot, likely concealed at the top or bottom of the front bezel, is a characteristic feature of this model, and its mechanical integrity appears complete.
- Connection Ports (Interfaces): DVI-D, DisplayPort (DP) video inputs, and USB hub connections (1 upstream, likely 2 downstream) are present on the rear panel. No physical damage such as rust or bent pins is observed in the port entries.
Accessories and Package Contents
The total number of parts shown in the visuals is not limited to the main unit.
- Main Unit: 1 EIZO monitor and its integrated stand.
- Box and Packaging: Original cardboard box perfectly fitting the device and shock-absorbing foams (styrofoam).
- Missing Items: Power cable, video cables (DisplayPort/DVI), or user manuals are not explicitly displayed in the visuals. However, there is a high probability they are inside the box. It is recommended that the buyer confirms the cable contents with the seller.
Size and Production Year
The panel size of the device is clearly stated on the label as 54.0 cm (21.3 inches). The production date, according to label data, is December 2018. Since medical monitors are long-lasting devices, a unit produced in 2018 still meets current usage standards.
Current Fault and Risk Analysis
There are no images of the device in operational (screen on) condition in the visuals, therefore no comments can be made regarding conditions such as “dead pixels” or “panel aging”. However, in physical inspection:
There is no evidence of any “current fault” such as breakage, cracks, liquid contact marks, or oxidation on the device. In terms of potential risk, the device’s “ventilation grilles” appear quite clean, suggesting it has not been over-operated in dusty environments. The presence of the box and protective foams has minimized the risk of damage during shipping or storage. The product appears mechanically reliable.