Secondhand Maxtec MaxO2 Oxygen Analyzer

Price: USD$ 210,00 Approx: 9.240,00 TL

, , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 07.01.2026

    Maxtec MaxO2 Oxygen Analyzer Analysis Report

    Device Identification

    The product displayed is a portable oxygen analyzer. The device consists of a main control unit, an external sensor probe connected to this unit with a coiled cable, and a zippered protective/carrying case that houses the entire set. It is a device used in the field of medical and industrial gas measurement technology.

    Brand and Model

    A detailed examination of the product’s front face reveals the “maxo2” logo in large blue letters below the screen. Directly beneath this logo is the inscription “OXYGEN ANALYZER”. At the very bottom frame of the device, the manufacturer’s brand name “maxtec” is clearly visible. In light of the visual data, the product’s brand has been identified as Maxtec, and its model as MaxO2.

    Authenticity

    The product’s body design, the font characters used (especially the typography specific to the Maxtec logo), the icon design on the membrane keypad, and its compatible structure with the original carrying case indicate that the device is an original Maxtec product. There are no visual indications (such as printing errors, incompatible parts, etc.) suggesting it is an aftermarket or counterfeit product.

    Areas of Use

    The Maxtec MaxO2 is designed to measure the oxygen concentration in a gas mixture. The primary areas of use for this device are:

    • Verifying the oxygen percentage at the output of medical ventilators, anesthesia machines, and oxygen concentrators.
    • Controlling the gas mixture delivered to patients in intensive care and respiratory therapy settings.
    • Analyzing oxygen tank filling rates in diving equipment.

    This analyzer is a compatible control and verification accessory for medical devices with an oxygen source or flow.

    Quantity Information

    A total of 1 (one) set is present in the visual. Set contents:

    • 1 Maxtec MaxO2 analyzer main unit.
    • 1 sensor probe and coiled cable connected to the analyzer.
    • 1 original carrying case.

    General Condition

    Visually, the device is in “used” condition. There are signs of use on the body, but the device’s integrity is preserved. The active display indicates that the device is receiving power and operating. Since the device has been stored within its protective case, it appears physically clean.

    Physical Deformations

    No significant cracks, fractures, or dents were detected on the device casing. On the surface where the keypad is located, especially around the power button in the lower right corner, a slight lifting or wear mark is visible on the membrane coating. Minor discoloration (yellowing/beige-ing) that may occur over time on the plastic casing is consistent with normal use.

    Mechanical Components

    The device’s outer casing, zippered carrying case, and mesh sensor compartment appear mechanically sound. There is no visible damage to the zipper mechanism of the case or the body of the sensor.

    Electronic Components

    At the time of the visual, the device’s screen is observed to be on. The LCD display is clearly readable, with no signs of dead pixels or screen cracks. The physical placement of the device’s power button and other membrane keys (Up, Down, Calibration) is proper.

    Accessories

    The device is located within a specially protected black carrying case. An external oxygen sensor is held within a mesh pocket in the left compartment of the case. The sensor is connected to the main unit with a black, flexible coiled cable. No breaks, deformations, or signs of excessive tension are visible on the cable. Although the socket entries cannot be clearly discerned from the visual, the point where the cable is attached to the device appears secure.

    Battery Status

    The device’s screen is operational, indicating that its internal batteries (typically powered by AA batteries) are still providing energy. However, the battery charge level or the physical condition of the batteries (e.g., leakage) cannot be commented on based on the visual.

    Screen Analysis

    The text “00.0%” is displayed on the LCD screen. A percentage sign is present in the upper right corner. No “Low Bat” warning is visible on the screen.

    Size and Compatibility

    The device has a portable (handheld) design, sized to fit in the palm of one hand. It is in the form of a standard medical measurement device.

    Existing Malfunctions and Potential Risks

    The most significant technical detail in the visual is the screen reading:

    • Observation: The device screen shows a value of “00.0%”.
    • Analysis: Oxygen analyzers should read approximately 20.9% or 21% oxygen in normal ambient air. The screen showing “00.0%” indicates that the device is not currently measuring ambient air or that there is a problem with the sensor.
    • Possibilities:
      • The sensor may have reached the end of its life (oxygen sensors are consumables and deplete over time).
      • The device may require calibration.
      • The sensor probe may be in a closed or airless environment (although the inside of the bag is not considered completely airless).

    While the device appears physically sound, due to the “00.0%” reading, it may require a new oxygen sensor or professional calibration before being put into use. This could be a signal of a malfunction or simply an indication that it is time to replace the sensor.