Secondhand Rotem Ram Gam-1 Gamma Survey Meter

, , , ,

Price: USD$ 100,00 Approx: 4.500,00 TL

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 17.11.2025

Rotem RAM GAM 1 Radiation Measurement Device Analysis Report

Overview and Product Description

The product shown in the images is a portable measuring device used to measure radiation levels. The device measures the ambient radiation rate in mR/h (milliRoentgen/hour) and displays it on its digital screen. The product is designed for safety and control purposes in environments where radiation is present, such as industrial, medical, or research settings. The images show 1 unit of the measuring device, its original box, and a user manual.

Brand and Model Information

A detailed examination of the device’s front face and rear label clearly shows its brand as Rotem and its model as RAM GAM 1. On the rear label, the model information is also stated as RAM GAM-1 RUGG. and MODEL: 4-0029. In the user manual, the model is referred to as RAM GAM-1 M. This information confirms that the product is a RAM GAM 1 series device manufactured by Rotem Industries.

Physical Condition and Cosmetic Assessment

The overall condition of the device is very good, and it is assessed as having been used minimally. No significant physical deformation such as scratches, cracks, dents, or discoloration was observed on its black casing. The device has a clean appearance, and its labels are legible. The fact that the device is stored in its box with bubble wrap packaging indicates careful use.

Electronic and Mechanical Components Analysis

  • Electronic Components: The device’s screen is functional and displays “0.00 mR/h”. This indicates that the device is active and performing measurements. No pixel errors or abnormalities are present on the screen.
  • Mechanical Components: The ON/OFF, RESET buttons and the button controlling the audible alarm on the front panel are physically sound. There are no signs of wear or sticking. On the side of the device, there is an external power input (socket) labeled “Ext. 9Vdc”, which appears clean and undamaged. The battery cover on the rear is secured with screws, and there are no signs of forced entry or damage around the cover.

Label and Certification Information

The device has multiple informative labels. The information obtained from these labels is listed below:

Rear Panel Label:

  • Brand / Model: RAM GAM-1 RUGG.
  • Model Code: 4-0029
  • Serial Number (S/N): 1908-063
  • Manufacturer: MADE BY ROTEM INDUSTRIES
  • Certification: The CE mark is present.

Side Panel Calibration Label:

  • Institution: TURKISH ATOMIC ENERGY AUTHORITY Çekmece Nuclear Research and Training Center Secondary Standard Dosimetry Laboratory
  • Calibration Date: 22.04.2024
  • Next Calibration Date: 22.04.2025

The presence of this calibration label and the fact that its validity period is ongoing indicate that the device is regularly inspected and its measurement accuracy is confirmed until the specified date.

Accessories and Package Contents

The accessories included with the device in the images are:

  • Box: A plain, white cardboard box where the product is stored is present.
  • User Manual: A user manual bearing the titles “Rotem Industries Ltd” and “RAM GAM-1 M” is seen inside the box.
  • Protective Packaging: The device is wrapped in bubble wrap packaging to prevent damage during transport.

No other accessories such as an external power adapter or connecting cable are visible in the images.

Potential Risk Assessment

A detailed examination of the device through the images revealed no physical damage, wear, rust, or cable crimping that would indicate a malfunction. The device’s excellent overall condition, its storage in its box and protective packaging, and most importantly, the presence of a current calibration label from an authorized institution, all indicate a low potential risk of malfunction. The device is expected to operate without issues in its current condition.