Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 09.06.2026
Report code: 1781016384
EPIGOLD Classic Blend Epilation Device Analysis Report
Device Identification and Brand Model Information
The images show an epilation device and its accessories. The “Classic Blend” text and “Epigold” logo are clearly visible on the front panel of the device. Based on this information, the brand of the device has been identified as EPIGOLD and the model as Classic Blend.
Authenticity Assessment
Upon examining the general appearance, logo quality, and placement of the labels, the impression is that the product is original. The craftsmanship and material quality appear to meet the standards.
Usage Areas
This device is used for the permanent removal of unwanted hair using the needle epilation method. It is suitable for professional use in the fields of cosmetics and dermatology. The “Blend” feature of the device aims to provide more effective results by combining thermolysis and galvanic epilation methods.
Quantity Information
- Main Unit (Epilation Device): 1 piece
- Foot Pedal: 1 piece
- Handpiece (Probe Pen): 1 piece
- Wrist Strap (Grounding Electrode): 1 piece
General Condition and Physical Deformation
Although the device has been used, it is in good condition. No significant scratches, dents, cracks, or discoloration have been observed on the casing. There is slight dust on the surfaces, but this does not affect the functionality of the device.
Mechanical and Electronic Component Inspection
The rotary knobs (Timer and Power) and push buttons (Start, Reset, Mode) on the front panel of the device appear to be intact. The connection sockets (for the probe and foot pedal) are clean and show no signs of deformation. It is understood that the digital display is in working order and clearly shows the numbers. No visual issues have been detected in the mechanical and electronic components of the device.
Accessories
The device comes with one foot pedal, one handpiece (probe pen), and one wrist strap. It is observed that all cables are intact and there are no breaks or crushing at the connection points. There is no expiration date information on the accessories.
Battery Status
There is no information or battery compartment visible in the images indicating that the device has an internal or external battery. It is assumed that the device is powered directly from the electrical grid.
Label Information
Specific label information such as serial number, lot number, or REF code is not clearly readable in the images. There are functional labels on the front panel of the device such as “Treatment Time”, “Timer”, and “Power”. These labels indicate the adjustable parameters of the device during use.
Display Analysis
There is a red, two-digit digital display on the front panel of the device. The value “8.8” is visible on the display. Below the display, there are “Start”, “Reset”, and “Mode” buttons. This display is used to show settings such as treatment time or power level. The buttons are used to control the operating modes and settings of the device.
Dimensions and Compatibility
There is no information regarding the exact dimensions of the device in the images. However, it is observed that the device has a compact structure suitable for desktop use. It is estimated that the accessories are compatible with standard epilation probes and electrodes.
Year of Manufacture
There is no direct information regarding the year of manufacture on the device or its labels. The general design and material structure of the device indicate a modern but several-year-old production period. Considering that such devices are used for many years, it could be a current model or a previous generation model.
Documents
There are no documents such as invoices, warranty certificates, user manuals, or certificates belonging to the device in the images. Therefore, no additional documentation information that could be presented to the buyer has been identified.
Usage Duration
There is no information regarding the usage hours or total operating time on the device’s display, labels, or in the images. This data could not be determined from the images.
Existing Fault
No clear signs of failure such as broken parts, error messages, broken cables, or missing components that would prevent the device from operating have been detected in the images. It is understood that the device is visually functional.
Potential Fault Risk
The general condition of the device is good. No concrete details that could pose a potential risk of failure, such as severe wear, rust, or cable crushing, have been observed in the images. All connection points and cables appear to be solid.