Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 03.10.2026
Report code: 1791013444

Medical Laser Hair Removal Device Analysis Report

Device Identification and Identity Information

The examined product is a professional medical laser hair removal device featuring a wheeled body, a large screen on the upper section, and two application handpieces. There is no brand name or model code indicated in the images; therefore, brand and model information is not included in the report.

Usage Areas and Compatibility

The device is used in dermatology and aesthetic centers to perform permanent hair removal and epilation procedures by targeting hair follicles. According to the technical data on the screen, the device supports different wavelengths, specifically 755nm, 808nm, 940nm, and 1064nm; this feature allows for applications suitable for various hair and skin types.

Quantity Information

The images show the main body, two application handpieces connected to the device, mobile transport wheels, and an integrated control screen as a whole. The total product and main accessory structure consist of these components.

General Status and Condition

The device is generally clean and in good condition. No significant discoloration or deformation is observed on the outer plastic casing. It is understood that the device is in working order, as evidenced by the active screen and illuminated interface lights.

Physical Deformation

There are no cracks, deep scratches, or dents on the black plastic surfaces of the main body or the handpiece housings. The physical integrity of the wheels and connection parts is intact.

Mechanical Components

The side slots carrying the application handpieces, the emergency stop button, the key lock mechanism, and the wheels located at the bottom move without any issues. The flexible hoses connecting the handpieces to the main body and the mechanical connection points are in place and stable.

Electronic Components

The electronic components of the device are controlled via the touchscreen located on the top and the emergency stop switch on the front panel. There are no signs of darkening, burning odors, or external damage to the electronic components.

Accessories

There are two application handpieces integrated into the device body and flexible transmission lines connecting these handpieces to the device. The power key, which ensures the safety of the device, is inserted into the front panel. Wheels providing mobility are present at the bottom of the device.

Battery Status

There is no data or battery compartment in the images indicating the presence of an internal or external battery; the device operates directly on mains electricity.

Label and Text Inventory

There are laser warning labels with black symbols on a yellow background on the application handpieces of the device. These labels are safety warnings indicating that the device emits laser radiation and that direct eye contact should be avoided. Since labels belonging to the rear or side panels of the device body are not visible in the images, technical data from these areas is not included in the report.

Screen Analysis

An active user interface is displayed on the large touchscreen at the top of the device. The INTELLIGENT inscription and user profile icons are located in the upper middle part of the screen. The 755nm+808nm+940nm+1064nm wavelength combinations are written at the bottom of the screen; this indicates that the device incorporates four different wavelength technologies simultaneously. Data read on the screen includes a frequency value of 3 Hz, an energy density of 10 J/cm², and a total energy value of 10.0 kJ.

Dimensions and Compatibility

There is no label containing units regarding the physical dimensions, weight, or dimensional values of the device in the images. The form of the product is in the size of a standard vertical-type laser device designed for use in a clinical environment.

Year of Manufacture

There is no date information regarding the year of manufacture on the outer surface or in the screen menus of the device. The design lines and digital interface structure point to modern technology, but no date is specified as there is no concrete year data.

Documents

There are no invoices, warranty certificates, user manuals, or any similar written documents in the images.

Usage Duration

There is no counter information on the screen or labels of the device indicating the total operating hours or usage duration.

Existing Faults

No broken parts, disconnected cables, error codes, or any negative findings indicating a malfunction have been detected in the images.

Potential Fault Risk

There is no visible risk of wear or tear at the connection points of the hoses attached to the application handpieces or on the body plastics; the device is generally in good condition.

Authenticity Assessment