Sold Out

Whatsapp »
SKU: MBP36PH19GA

Secondhand Elit SL-F601 Positioning Air Mattress

, , , ,

Price: USD$ 160,00 Approx: 7.200,00 TL

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    If there is a local operation center in the seller's country:

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    If there is no operation center in the seller's country:

    • Technical Inspection: Inspections are performed by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 23.02.2026

    ELIT SL-F601 Anti-Decubitus Air Mattress System Analysis Report

    Device Identification

    The product examined in the visuals is a motorized (compressor-equipped) air mattress system designed to prevent the formation of pressure sores (decubitus) in bedridden patients and to aid in the healing of existing wounds. The system consists of a main control unit (pump) that manages air pressure and an air-channeled mattress on which the patient lies. The product is a medical treatment and care support device.

    Brand and Model Information

    During the detailed visual inspection, the brand and model information was clearly identified on the device’s front panel and the top surface of the mattress.

    • Brand: ELIT
    • Model: SL-F601
    • Product Description: ANTI-DECUBITUS SL MATTRESS SERIES
    • Manufacturer: BEIJING SHENLU MEDICAL DEVICE CO., LTD

    Areas of Use

    This system is used in patients who must lie down for extended periods to relieve blood circulation by reducing pressure on tissues and to prevent the formation of bedsores. It is suitable for use in intensive care units, palliative care centers, and for paralyzed or bedridden patients requiring home care. As understood from the “Turn” buttons and indicators on it, the SL-F601 model has the ability to position the patient left-right (rotation).

    Quantity and Component Information

    The overall set integrity in the visuals is as follows:

    • 1 ELIT brand control unit (Air pump/compressor).
    • 1 blue-colored mattress with air cells.
    • Multi-air hose assembly connecting the control unit to the mattress (Blue, orange, and yellow colored hose group).
    • Integrated power cable.

    General Condition and Physical State

    According to the label data, the product was manufactured in 2021 and is a used device. Its physical integrity has been preserved. The mattress shows normal creases due to use and folding, but there is no visual data indicating tears or punctures. The external casing of the pump unit has slight signs of use, stains, and dust accumulation on the plastic surface due to its shelf life. No serious cracks or fractures have been observed.

    Front Panel and Control Functions Analysis

    Upon examining the device’s front panel, the following control mechanisms and functions were identified:

    • Pressure Adjustment: A manual pressure adjustment knob (potentiometer) with “Soft and Hard” markings and an increasing scale from left to right is present. The knob is grey and mechanically in place.
    • Mode Buttons: There are three physical buttons on the panel: “Supine”, “Turn”, and “Alarm Stop”.
    • LED Indicators: Green illuminated indicator areas displaying the device’s status are present: “Supine”, “Low Turn”, “Medium Turn”, “High Turn”. Additionally, there is a red square warning area designated for “Alarm”.
    • Language Option: All instructions on the panel (Soft, Hard, Supine, Turn, etc.) are in Turkish.

    Label and Technical Data

    The silver-colored manufacturer’s label on the back of the device is legible and contains the following technical data:

    • Voltage: AC220V ± 22
    • Input Power: 15W
    • Frequency: 50Hz
    • Pressure: ≥ 8Kpa
    • Flow Rate (Air Flow): ≥ 6L/min (6 liters per minute and above)
    • Noise Level: ≤ 40dB
    • Fuse: 250V 0.2A
    • ID No: 0212F0501127
    • CE Certificate No: 02223
    • Ref Standard: The Ref code is not additionally specified in the visual, but the brand model SL-F601 is the reference.

    Year of Manufacture and Origin

    According to the data on the label, the device’s production date is 2021.05.01. The product’s origin is the People’s Republic of China (Made in China). The importer company is stated as “Okyanus medical Saglik urunleri tic. Ltd. Sti.”.

    Accessories and Connection Points

    The black power cable extending from the left side of the device maintains its integrity. The air hose group emerging from the front-left side has color-coded (blue, orange) inlets, and the hoses pass through a green protective sleeve (organizer). No kinking or breakage of the hoses is observed at the pump inlet. At the foot end of the mattress, white printed graphics (footprint icons) indicating foot position are present.

    Mechanical and Rear Design

    On the rear part of the pump, there are integrated grey plastic hanger brackets (hook structure) for suspending the device on a patient’s bed frame. No visible deformation or cracks are present on the hanger brackets.

    Potential Failure Risk Assessment

    During the visual inspection, no critical damage (casing crack, broken cable, crushed hose) that would prevent the device from operating was identified. However, considering the possibility of hose inlets (sockets) leaking air over time and slight dirt on the plastic components, it is recommended to perform an air leak test before starting use. Given the device’s age (approximately 5 years), checking the compressor performance (pressure generation) would be appropriate. The device, in its current state, appears to be in a “may require maintenance but is a candidate for operation” condition.