Approved

Ready For Sale

Whatsapp »
SKU: MBXJWAR81EY

Secondhand Richard Wolf 8564.021 Arthroscopi Shaver Handpiece

Price: USD$ 400,00 Approx: 17.600,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 17.12.2025

      RICHARD WOLF Surgical Handpiece Analysis Report

      Device Identification

      The images show a motorized surgical handpiece used in medical procedures (possibly endoscopy, urology, or gynecology). The product consists of a stainless steel body, a trigger/mechanism on it, a long black connection cable, and a special metal connection socket at the cable’s end.

      Brand and Model Information

      The information identified as a result of a detailed visual inspection is as follows:

      • Brand: The RICHARD WOLF logo is clearly engraved onto the product’s metal body using laser etching technique.
      • Model: While the device’s brand information and technical symbols are clearly legible, the specific code indicating the model number (e.g., 8XXX.XXX) could not be optically deciphered or was not within the angle in the visuals. Therefore, no estimated model number has been provided to avoid conveying incorrect information.

      Authenticity Status

      The quality of the laser engravings on the product’s body, the metal craftsmanship, the strain relief details at the cable connection points, and the type of special connector used strongly indicate that the product is an original RICHARD WOLF production.

      Technical Label and Mark Analysis

      The analysis of the technical markings located on the device body is as follows:

      • CE 0124: Indicates that the product is a medical device compliant with European health standards and has received approval from an authorized body.
      • INT 5min/3min: This marking indicates that the device operates on an “Intermittent” working principle. Technically, it means that after operating the device for 5 minutes, it should be rested for 3 minutes to prevent overheating and preserve motor life. This marking is commonly found in surgical handpieces containing an electric motor (e.g., morcellators or shaver systems).
      • IPX7: Specifies the device’s water resistance level. An IPX7 rating means the device is resistant to submersion in water for a specific duration and pressure, thus indicating its suitability for liquid sterilization or washing procedures.

      Areas of Use

      This device is a surgical handpiece used by connecting it to a control unit. As understood from the “INT” marking, it contains a motor mechanism. Considering the product range of the Richard Wolf brand, this handpiece is likely an active part of systems used for tissue resection, fragmentation (morcellation), or shaving procedures in fields such as urology or gynecology.

      Physical Condition and Deformation Analysis

      The external cosmetic condition of the device has been analyzed based on the visuals as follows:

      • Metal Body: The stainless steel body is generally in clean condition. No significant dents, deep scratches, or signs of rust are visible. The satin-finish surface is well-preserved.
      • Cable: The black connection cable retains its integrity. No peeling, cracking, or crushing of the cable has been detected in the visible parts. The cable has been neatly gathered with a plastic clamp for transport.
      • Mechanical Parts: The textured surface of the upper grip/locking mechanism or trigger part is clean and physically intact.
      • Connector: The metal socket (pin connector) at the end of the cable appears robust; no noticeable bending is observed in the pins or the outer periphery.

      Overall Condition and Status

      The product can be categorized as “Used/Good Condition”. It has a clean appearance, having undergone sterilization processes. The way the cable is coiled and its cleanliness indicate that the device has been maintained. Visually, there is no obvious damage that would impede its use.

      Accessories and Quantity Information

      • The visual shows 1 unit of a Richard Wolf surgical handpiece with an integrated cable.
      • No other accessories, control unit, tip, or blade are visible.

      Potential Malfunction Risk

      In the visual analysis, no signs of breakage, severed cables, or liquid contact (corrosion) that would directly affect the device’s functionality were found. The cosmetic condition of the device suggests that mechanical and electronic risks are visually low. However, since the operating performance of the internal motor (torque, sound, vibration) in such motorized handpieces cannot be assessed visually, it is recommended that the device undergo a technical service test before professional use.