Ready For Sale

Whatsapp »
SKU: MBD47OW84KR

Secondhand Eryiğit STR 4410 S 160 Liters Autoclave

, , , , ,

Price: USD$ 14.000,00 Approx: 630.000,00 TL

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 09.04.2026
Report code: 1775746183

Eryiğit STR 4410 S Steam Sterilizer Analysis Report

Device Identification and Usage Areas

The product in the images is a steam sterilizer (autoclave) suitable for industrial and medical use. It is used in hospitals, clinics, laboratories, and sterilization units to sterilize surgical instruments, medical textile products, and other heat-resistant materials using high-pressure steam.

Brand and Model

The brand of the device has been identified as Eryiğit, and the model as STR 4410 S.

Authenticity Assessment

The product is considered authentic based on the examination of the brand imprint on the front panel, the control panel design, and the detailed metal manufacturer label located on the side surface. The CE, TSE, ISO, and HYG CEN certification logos on the label support this assessment.

Quantity Information

1 steam sterilizer main unit and 1 metal wire shelf inside the chamber have been identified in the images.

General Condition and Physical Deformation

The device is in used condition. There are visible water stains, wiping marks, and superficial contamination on the stainless steel surfaces forming the outer casing, particularly on the left side panel and around the front door. No cracks, fractures, or deep dents have been observed on the body, door, or control panel of the device.

Mechanical Components

There are 4 analog pressure gauges on the front surface of the device. The glass and frames of the gauges are intact. The door mechanism, the inner chamber gasket, and the metal shelf inside the chamber maintain their physical integrity. The physical directional buttons and the key switch on the control panel appear to be mechanically sound.

Electronic Components and Screen Analysis

There is a Weintek brand digital touch screen on the front panel. There is no physical damage or crack on the outer surface of the screen. In the images, the screen is either off or displaying a blank white image; therefore, an interface or error message analysis could not be performed. Directly below the screen, there is a red emergency stop button, and at the very bottom, there is an internal thermal printer. There is a printed paper roll in the paper output slot of the printer.

Label and Technical Information

The data on the metal information label located on the side surface of the device is listed below.

  • Manufacturer Eryiğit Tıbbi Cihazlar A.Ş.
  • Device Type Steam Sterilizer
  • Model STR 4410 S
  • Serial Number 2017/01-093
  • Production Date 06/2017
  • Volume 160 LT
  • Power 20 kW
  • Chamber Operating Temperature and Pressure 140 C / 2.2 Bar
  • Chamber Test Pressure 7 Bar
  • Generator Operating Temperature and Pressure 150 C / 3 Bar
  • Generator Test Pressure 7 Bar
  • Vacuum Pressure 70 m Bar
  • Certificates and Standards CE 1783, TSE, EN 285, ISO 9001, ISO 13485, ISO 14001

Dimensions and Compatibility

According to the label information, the inner chamber capacity of the device is 160 liters. This volume is suitable for standard sterilization processes in medium and large-scale medical facilities.

Potential Failure Risk

No serious wear, rust, or structural damage that would prevent the operation of the device, create a security vulnerability, or require urgent repair has been detected in the images. The stains on the outer surface are purely cosmetic. The general condition of the device is good, and its structural integrity has been preserved.