Secondhand Nüve 4060V 75 Liters Autoclave

Price: USD$ 4.100,00 Approx: 180.400,00 TL

, , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 18.12.2025

    Nüve OT 4060V Vertical Steam Sterilizer Analysis Report

    Device Identification and Product Description

    The product in the image is an industrial-type steam sterilizer (autoclave) with a vertical chamber structure, used for sterilization processes in laboratory and and medical environments. The device features a stainless steel outer body, a heavy lid mechanism that opens upwards, and a built-in digital/analog control unit on the right side. It is a stationary unit designed as a floor-standing type.

    Brand and Model Analysis

    The front panel of the device and its labels have been examined in detail:

    • Model: The designation OT 4060V is clearly visible on the upper right control panel of the device. This code indicates the vertical steam sterilizer model.
    • Brand: Adjacent to the model number on the control panel, there is a characteristic logo featuring black geometric shapes on a yellow background. When this logo and the “OT 4060V” model code were verified with internet data, the device was identified as belonging to the Nüve brand.
    • Other Labels: On the upper left front part of the device, there is a label with “İndem” written on it, which appears to have been affixed later. This label is evaluated as an authorized service, distributor company, or institutional inventory tag. However, the original manufacturer is Nüve.

    Areas of Use

    This device is used in medicine, dentistry, veterinary, biotechnology laboratories, and food control laboratories for the sterilization of surgical instruments, textile products, glassware, and liquids with high-pressure steam.

    Quantity Information

    The image shows 1 unit of Nüve OT 4060V Vertical Steam Sterilizer and its integrated accessories (lid, hoses, panel). A part belonging to another device (blue-buttoned panel) whose tip is visible in the lower left corner is not included in this analysis.

    Originality and Label Information

    The control panel fonts, layout, stainless steel craftsmanship, and the quality of the industrial manometers on the device indicate that the product is an original factory production. Label details visible on the device:

    • Control Panel Label: The main panel with a black background, located on the right side, where the model code is found.
    • Brand/Service Label: The “İndem” label with a white background and a colored logo, located on the left side.
    • Calibration/Control Label: A small, circular, yellow label is also visible on the upper right corner of the front (likely a quality control or calibration label).

    General Condition and Physical State

    The overall cosmetic condition of the product has been assessed as “used but in good condition”.

    • Stainless Steel Body: The stainless steel panels forming the main casing are generally clean. However, slight surface stains or dullness due to wiping can be observed at the very bottom (areas near the base). The left side panel appears clean with light reflection.
    • Lid Mechanism: The device’s top lid is in the open position. The inner part of the lid is stainless steel and appears clean. There might be some darkening around the gasket seat due to normal use, but no significant damage is noticeable.

    Mechanical and Electronic Component Analysis

    Technical inspection notes based on the visual are as follows:

    • Control Panel: The interface with a membrane keypad structure appears robust. There are no signs of tearing or heavy wear on the buttons. Two digital display windows and LED indicators showing operational status are present.
    • Pressure Gauges (Manometers): Two analog manometers are located on the panel (likely one for chamber pressure and the other for generator pressure). No breaks or cracks are visible on their glass.
    • Emergency Stop Button: A red mushroom-headed, yellow-backed emergency stop button is present on the lower right part of the panel and appears physically sound.
    • Mechanical Switches: Above the emergency stop button, a rotary switch (toggle switch) is visible, and at the very bottom, a mechanical lock mechanism or key slot is present.
    • Top Lid and Lock: The lid’s locking mechanism (rotary lever and gear system) is of a heavy industrial type, and no parts appear to be missing. The piston or spring system that holds the lid open appears functional (the lid is suspended).

    Accessories and Connections

    Accessories visible with or attached to the device are as follows:

    • Drain Hose: A transparent, spiral-reinforced hose is visible emerging from behind the top lid. This hose is likely used for steam discharge or overflow. Slight yellowing due to use might be present in the hose’s color.
    • Power Cable: A thick, black-insulated industrial-type electrical cable is seen emerging from the lower left side of the device, with a red (likely 3-phase / Trifaze) industrial-type plug (socket) at its end. This indicates the device’s high power requirement.

    Battery and Power Status

    This device is an industrial product powered by mains electricity (the 3-phase plug in the image). It does not have an internal battery, and no battery unit is visible in the image. It is not a rechargeable device.

    Screen Analysis

    Since the device is off (unplugged or power disconnected), digital data on the screen cannot be read. Process steps (Heating, Sterilization, Drying, etc.) are indicated by text next to LED lights on the membrane panel, but the image resolution is not sufficient to read these small texts.

    Current Fault and Risk Assessment

    No broken parts, missing components, or severe corrosion that would impede the device’s operation were detected during the visual inspection.

    • Potential Fault Risk: The device appears to be second-hand. Since the sealing gasket of the top lid cannot be fully verified from the image, it is important to perform gasket elasticity and steam tightness tests before use. Furthermore, the calibration of mechanical manometers may lose its accuracy over time. However, these points are mentioned only as precautionary measures, and there is no clear evidence of a fault in the image.

    Conclusion

    The reported Nüve OT 4060V device is an industrial sterilization unit that maintains its physical integrity and appears complete with its control panel, lid mechanism, and connection cables. The cleanliness of the outer body and the robust appearance of the components indicate that the device may be well-maintained.