Don't Want To Buy At This Price?
Sorry. This product has been sold. You cannot bid. Please check out other products.
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 24.02.2026
Nüve OT 032 Steam Sterilizer (Autoclave) Analysis Report
Device Identification and Brand/Model Analysis
The device shown in the visuals is a desktop steam sterilizer (autoclave) used in laboratory and medical environments. As a result of the visual analysis, the identity of the device has been determined as follows:
- Brand: NÜVE (Logo is present on the front panel’s bottom right corner and on the control panel).
- Model: OT 032 (Clearly written in a yellow handwritten font on the front panel).
- Product Type: Laboratory type steam sterilizer.
Areas of Use and Overview
This device is used for the sterilization of surgical instruments, textile products, and heat-resistant plastic/glass materials with saturated steam in medical, dental, veterinary, and general laboratory applications. It is understood from the model designation (032) that it belongs to the 32-liter capacity class.
Quantity Information: The visuals show 1 main device and 1 perforated shelf placed inside the device’s chamber. No other accessories are visible.
Physical Condition and Cosmetic Examination
The outer casing of the device is made of white metal with electrostatic powder coating. In light of the visuals, the cosmetic condition analysis is as follows:
- General Casing Condition: The front, top, and side panels of the device generally appear clean. No significant dents, deep scratches, or rust have been detected.
- Front Panel: A very small brown stain (possible start of corrosion or dirt) is visible on the left-middle part of the lid. A yellow warning label and an ISO certification label are present on the lid.
- Rear Panel: Made of stainless steel. Its physical integrity is complete, and the screws are in place.
Mechanical Components and Inner Chamber (Boiler) Condition
The mechanical components and sterilization chamber of the device have been examined in detail:
- Lid Mechanism: The front lid features a long-handled mechanical locking system (lever type) that ensures closure. The handle is made of black bakelite/plastic material and appears sturdy. The lock housing is metal.
- Inner Chamber: The chamber part is made of stainless steel. There is no visible corrosion, pitting, or deep deformation within the chamber. The metal surface maintains its shine.
- Shelf System: A sliding system and one perforated stainless steel protective shelf are present inside the chamber at the base.
- Gasket/Lid Gasket: A sealing gasket is located on the inner side of the lid. Visually, no tears are seen in the gasket, but the flexibility of the rubber material cannot be tested from the visual.
Electronic Components and Control Panel
Upon examining the control unit and display panel located on the right front side of the device:
- Panel Type: A digital control unit with a membrane keypad and an LCD screen is present.
- Buttons and Indicators: Function buttons such as “Start/Stop”, “Alarm”, and adjustment arrows are present. LED indicator areas showing process stages (Lid Open, Full Drain, Water, etc.) are located on the panel surface. No cracks or tears are visible on the panel surface.
- Rear Connections: On the rear right side of the device, there is a standard IEC power input (power socket), a green illuminated On/Off switch (rocker switch), and a red-colored probable safety thermostat/fuse holder.
Label and Warning Sign Analysis
The labels on the device are legible and contain critical safety information:
- Front Warning Label: In the upper left corner, there is a warning “DO NOT OPERATE WITHOUT READING THE USER MANUAL”.
- Quality Label: A yellow “ISO 9001” certification label is affixed on the upper right front.
- Hot Surface Warning: Inside the upper part of the chamber lid, there is a yellow triangle with the inscription “DIKKAT! SICAK YÜZEY / ATTENTION! HOT SURFACE”.
- Grounding Warning: On the rear panel, above the power input, there is a warning “Operate the device with a grounded outlet”.
- Manufacturing Label: In the middle of the rear, a metallized type label and below it a blue service/calibration tracking label are visible.
Conclusion and Risk Assessment
As a result of the visual analysis, the general condition of the Nüve OT 032 autoclave device has been determined to be in good and used condition. The device’s integrity is complete.
- Current Fault Indication: No fault indications that would prevent the device from operating (broken screen, disconnected cable, missing part) have been found in the visuals.
- Originality: All parts, labels, and panel structure conform to Nüve brand’s original production standards.
- Potential Risk Note: Due to being a pressure vessel, the elasticity of the lid gasket and the rear safety valve/thermostat may require physical inspection before commissioning. As the device is second-hand, the tactile sensitivity of the membrane buttons cannot be verified from the visuals.