Don't Want To Buy At This Price?
Sorry. This product has been sold. You cannot bid. Please check out other products.
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 03.02.2026
Nüve OT 4060V Vertical Type Steam Sterilizer Analysis Report
Device Identification
The device shown in the visuals is a vertical steam sterilizer (autoclave) used for industrial and medical purposes. The device is a laboratory/clinical equipment with a stainless steel body, wheeled structure, and a top-loading lid system.
Brand and Model
As a result of a detailed examination on the device’s front control panel, the following identification information has been determined:
- Brand: NÜVE (Panel design language, logo placement, and model number standards belong to the Nüve brand.)
- Model: OT 4060V (The inscription “OT-4060V” is clearly visible in yellow font on the upper right corner of the control panel.)
General Condition and State
Upon examining the device’s exterior aesthetics, it is observed that its general condition is good and it has been used cleanly despite its second-hand status. The stainless steel outer panels retain their shine, and no significant corrosion, rusting, or deep dent marks have been found.
Physical Deformations and Exterior Body Analysis
The product’s body consists of stainless steel panels. During inspections based on the visual:
- No significant deformation, dents, or scratches have been detected on the side and front panels.
- The casing joints and lid gaps appear regular.
- The yellow “Q” label (presumably Quality Control approval) located on the upper front part is intact and shows no wear.
Mechanical Components
The mechanical parts of the device appear to be in place:
- Top Lid: The domed pressure lid located on the top of the device appears sturdy. No visual breakage or cracks have been observed in the white, corrugated hose (steam exhaust or connection hose) attached to the lid. The hose connection fitting is in place.
- Water Level Indicator: The vertical glass water level indicator reservoir located on the lower left side of the front panel is intact and does not appear broken.
Electronic Components and Control Panel
The control unit located on the front right side has been examined in detail:
- Keypad: The membrane keypad placed on a blue background is not deformed and shows no signs of tearing or wear.
- Displays: There are digital display areas on the panel (values are not readable as the device is turned off in the photograph).
- Manometers: There are two analog pressure gauges (manometers) on the panel. The gauge glasses are intact, with no cracks.
- Switches and Buttons: The “Acil Stop” (Emergency Stop) button stands out clearly in red and appears sturdy. Immediately above it, there is a green illuminated on/off switch.
- Printer Slot: Below the keypad, there is a slot presumed to be for a thermal printer.
Labels and Warning Signs
Labels indicating operational safety and identity are present on the device:
- Model Label: “OT-4060V” on the upper right of the panel.
- Hot Surface Warning: A safety label with the warning “Sıcak Yüzey / Hot Surface” in a black triangle on a yellow background is located on the top lid.
- Q Label: Yellow square “Q” label on the front.
- Emergency Stop Label: A yellow, internationally standardized “Emergency Stop” label is located around the red button.
Areas of Use
The Nüve OT 4060V is a device that performs sterilization using pressurized steam. Its areas of use include:
- Hospitals and medical centers (surgical instrument sterilization).
- Laboratories (glassware and culture media sterilization).
- Dental clinics and veterinary services.
- Sterilization processes before textile and medical waste disposal.
Quantity Information
There is 1 (one) vertical type steam sterilizer in the visual.
Accessories
No external accessories (basket, spare parts, external cables, etc.) are visible in the visual, other than the parts mounted on the device itself.
Potential Malfunction Risk and Evaluation
Based on visual inspection, no obvious physical damage requiring “urgent repair” has been detected on the device. Although it cannot be determined from the visual whether the white hose on the top lid has hardened over time due to heat, its integrity is currently preserved. The cleanliness of the electronic panel suggests that the device has been used carefully. However, since it is a pressure vessel, manometer calibration and gasket (the condition of the gaskets cannot be seen in the visual as the lid is closed) sealing should be checked with an operational test.