Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 19.09.2026
Report code: 1789818856
Biotes Pharma BW 385 L Device Analysis Report
Device Identification and Identity Information
The main product examined in the images is a medical device used for heating medical fluids and blood. The Biotes Pharma brand logo and the BW 385 L model code are located on the top panel of the device. There are no additional parts belonging to any other brand or model on it.
Authenticity and Production Period Assessment
The brand logos, label placement, and panel prints on the product comply with the original manufacturer’s standards. The year 2012 is marked on the yellow maintenance label located on the top of the device; this indicates that the production or maintenance period of the device is 2012.
Usage Areas
This device is used in clinics, operating rooms, and intensive care units to heat infusion fluids and blood products to body temperature before they are administered to the patient. It ensures that patients are protected from the risk of hypothermia during medical treatment processes.
Quantity Information
In the images, there is one blood and fluid heating device connected to the main body and one electrical cable wrapped around it. The total number of parts is as stated.
General Condition and Physical State
The device is generally in a used condition, with slight yellowing and superficial marks on its white plastic casing and control panel. There are handwritten tape labels on the panel.
Physical Deformation
There is a small crack or fracture mark taped or covered on the top left corner of the device’s main body. Color changes and dirt residues due to the duration of use are visible on the casing.
Mechanical Components
The black corrugated mechanical section surrounding the device and the wrapped cable arrangement at the bottom are in place. The green on/off button located in the middle is mechanically intact and functional.
Electronic Components and Display Analysis
There is a digital temperature display panel and a green power light on the front of the device. The panel features temperature graduation lines ranging from 37 degrees to 41 degrees; this indicator allows for the monitoring of the temperature of the administered fluid.
Accessories and Connection Points
A white mains connection cable and plug are attached, wrapped around the bottom of the device. No breaks or crushing are visible on the cable.
Battery Status
There is no external or internal battery compartment or battery slot visible in the images; the device operates directly via mains electricity.
Label and Text Inventory
The texts read on the top panel and labels of the device are as follows: Biotes Pharma logo, BW 385 L model code, hat icons, POWER, NETZ, 37° – 41°C temperature range scale, and the yellow next maintenance (nächste Wartung) label from 2012 on the top surface. Additionally, there are handwritten instruction tapes on it. The maintenance label indicates that the device has undergone technical inspection in the past.
Dimensions and Compatibility
There is no numerical millimeter value regarding the physical dimensions or measurements of the device in the images. The device is designed to be compatible with standard infusion and blood sets.
Documents
There are no invoices, warranty certificates, user manuals, or any printed official documents in the images.
Usage Duration
There is no digital counter or label information on the device indicating the total operating hours or lifespan.
Existing Fault
It is clearly visible in the images that there is a break or crack in the top left casing of the device. This indicates that there is physical damage to the outer casing.
Potential Fault Risk
The broken and cracked area on the casing may increase the risk of liquid contact with the internal parts of the device. Furthermore, plastic fatigue due to long-term use is observed.