Sold Out

Whatsapp »
SKU: MB5TQ47IO8L

Secondhand Elektro-mag M 19 Micro Haematocrit Centrifuge

Price: USD$ 650,00 Approx: 28.600,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 06.01.2026

    Elektro-mag M19 Hematocrit Centrifuge Device Analysis Report

    Device Identification and Description

    The device in the examined visuals is a microcentrifuge used for separating blood samples in laboratory environments. It is specifically defined as a “Microhaematocrit Centrifuge”. The device is suitable for desktop use, has a compact structure, and is equipped with an electrically powered motor.

    Brand and Model Information

    The brand and model identification has been definitively made based on clear information on the device’s front panel, top cover, and rear label. The product’s brand is Elektro-mag, and its model is designated as M19. The model definition on the device’s rear label is precisely “M19 Hematokrit Santrifüj”. It is understood from the label information that the manufacturer is Istanbul/Turkey based “Elektro-mag Lab. Alet. San. Tic. A.Ş.”.

    Originality and Workmanship

    Upon examining the print quality of the labels on the product, the embossed hexagonal logo on the rear panel, model designations, and the structure of the materials used (hinges, switch group, paint quality), it is observed that the product is 100% original Elektro-mag production. The labels are neatly placed and comply with industrial standards.

    Areas of Use

    This device is used in medical laboratories, especially in hematology units, to measure hematocrit (HCT) values by separating cellular components of blood (especially red blood cells) from plasma. It allows for the high-speed (10,000 rpm) centrifugation of blood samples taken into capillary tubes. It is suitable for use in clinics, hospitals, veterinary clinics, and blood banks.

    Quantity Information

    The visuals show 1 (one) main body of a centrifuge device. The device’s power cable or box is not prominently displayed in the visuals; the focus is solely on the device itself.

    General Condition and Cosmetic Examination

    The device is in used condition. Its general cosmetic condition is medium-good. The most prominent cosmetic flaw is the “cartoon character girl, clouds, and hearts” stickers that have been subsequently affixed by the user to the device’s front control panel (the blue area containing the Elektro-mag logo and speed/time settings). These stickers are not part of the original design.

    Physical Deformation

    No significant dents, cracks, or breaks have been detected on the device’s outer casing (beige-colored part). However, slight dullness due to age may be present on metal components and painted surfaces. While the metal hinges at the back appear sturdy, minor superficial oxidation or signs of metal fatigue on them are within normal use limits.

    Mechanical and Internal Component Analysis

    Upon examining the rotor (rotating head) section visible when the device’s lid is opened:

    • Rotor Type: There is a hematocrit rotor with numbered slots from 1 to 24. This indicates that the device can process 24 samples simultaneously.
    • Gasket Condition: The gray rubber gasket around the chamber appears to be in place and intact, but upon closer inspection, it shows signs of use and minor dirt.
    • Rotor Lid: A metal rotor lid and a central locking nut are present. It has been visually determined that the nut is in a condition to be tightened.

    Electronic Components and Controls

    The front panel features a mechanical rotary knob (Timer) used for time setting. The knob cap is in place. The panel also has an indicator (red LED-like) window showing that the device is operating or connected to power. At the rear, the “On/Off” (0/1) power switch, presumed to be green-lit, is sturdy and seated in its slot.

    Label Information and Technical Specifications

    The technical data on the gray label on the device’s rear panel are as follows:

    • Model: M19 Hematokrit Santrifüj
    • Manufacture Date: 07/03/2018
    • Serial No: 18030707
    • Speed: 10000rpm (Fixed speed)
    • Weight: 9 kg
    • Power Ratings: 190/240V, 2A, 100W, 50Hz
    • Protection Class: IP 22
    • Compliance: CE mark is present.

    Manufacturing Year and Usage Period

    The manufacturing date of the device is March 7, 2018. Based on this date, the device has a history of approximately 7-8 years. Since there is no digital display, the total operating hours cannot be visually determined.

    Accessories and Connection Points

    At the rear of the device, there is a standard IEC type power input (socket) with a fuse holder. A power cable attached to or next to the device is not clearly visible in the visuals; this part may need to be supplied separately.

    Existing Faults and Potential Risk Analysis

    There is no visual evidence (broken parts, burn marks, etc.) indicating that the device is “Faulty”. The device maintains its mechanical integrity. However, in such devices with mechanical timers (analog timer) and brush motor technology, the wear of motor brushes or the loss of sensitivity of the timer spring are common occurrences over time. The buyer should consider that the device was manufactured in 2018 and requires regular maintenance (rotor cleaning, balancing). The possibility of stickers on the front panel leaving residue if removed should be noted as a cosmetic risk.