Ready For Sale

Whatsapp »
SKU: MBZEZZYH345

Secondhand Elektro-mag M 815 A Centrifuge

, , , ,

Price: USD$ 800,00 Approx: 36.000,00 TL

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      If there is a local operation center in the seller's country:

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      If there is no operation center in the seller's country:

      • Technical Inspection: Inspections are performed by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 20.02.2026

      Elektro-mag M 815 A Laboratory Centrifuge Analysis Report

      Device Identification

      The device in the examined image is a desktop laboratory centrifuge used to separate biological or chemical samples according to their density. The product consists of a single-piece main unit.

      Brand and Model

      The writings and logos on the product in the image have been thoroughly examined. The manufacturer’s logo and name elektro-mag are clearly visible in the bottom right corner of the device’s control panel. On the blue strip on the left side of the device’s top lid, the model number M 815 A is clearly legible. In light of this visual evidence, it has been confirmed that the brand of the device is Elektro-mag and its model is M 815 A. Additionally, the product’s description “GENERAL PURPOSE LABORATORY CENTRIFUGE” is stated on the control panel.

      Originality

      The brand logos on the device, the placement of labels, the model number printing, and the quality of industrial design indicate that the product is an original Elektro-mag production. No inconsistencies suggesting it might be an aftermarket or copy product have been observed.

      Areas of Use

      This device is used in laboratory environments (hospitals, research centers, universities, etc.) to separate blood tubes or other liquid mixtures into their components by spinning them at high speeds. It is generally a basic piece of equipment in medical analysis processes such as obtaining serum, separating plasma, or performing urine sediment analysis.

      Quantity Information

      There is 1 main device in the image.

      General Condition and State

      The device appears clean and well-preserved from the outside. Despite being cosmetically used, it is in good condition. No signs of yellowing or significant wear on the body are immediately apparent.

      Physical Deformation

      Upon examination of the product’s outer casing (body and lid), no deep scratches, breaks, cracks, or dents have been detected. The plastic components retain their white color. The lid fits properly, and no misalignment is observed.

      Mechanical and Electronic Components

      In the image, the internal rotor (rotating part) of the device is not visible because the lid is closed, so there is no visual data regarding the rotor type. The control panel on the front of the device and the rotary control knob (encoder) located beneath it appear intact. The electronic panel appears active, and the screen is operational.

      Screen Analysis

      The device features a color TFT LCD screen on its front panel. The screen is on and active in the image. The following information can be read on the screen:

      • Orpm: It is understood that the device is currently in a stopped position (0 revolutions/minute).
      • Menu Options: Program memory options such as “CGF”, “RPM”, “P1, P2, P3, P4, P5” are visible on the device’s interface.
      • Command Indicators: Command buttons or status indicators such as “START”, “STOP”, “PULSE”, and “LID” are present on the screen.

      Labels and Warning Texts

      English warning texts are located on the blue strip where the device’s body and lid meet. The legible parts from the image are as follows:

      • PLEASE PRESS TO CLOSE LID PROPERLY: Please press to close the lid properly.
      • WITH EQUAL WEIGHTS: Warning that the rotor should be balanced with equal weights.
      • THE USER’S MANUAL: Reference to the user’s manual.
      • YOU READ “COMPLETED” ON DISPLAY: Warning not to open the lid until “completed” is read on the display.

      Accessories and Connections

      A black power cable partially emerging from the left side of the device is visible. Other than this, no external accessories (rotor buckets, spare tube carriers, etc.) or warranty certificate are visible in the image.

      Existing Malfunctions and Potential Risks

      There is no physical evidence in the images (broken part, error code on screen, etc.) indicating that the device is faulty. The screen displaying “0rpm” suggests that the device is in standby mode and its electronic system is powered. There is no visible deformation in the cables or rust marks on the casing. The product appears ready for operation and risk-free in terms of its general condition.