Ready For Sale
Secondhand Lifotronic PV-100 Vest Therapy Machine
Price: USD$ 3.500,00 Approx: 157.500,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Free Shipping Conditions
You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.
Conditions
- The product must be sold for $500 USD or more.
- Both the buyer and the seller must be located in Turkiye.
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 14.02.2026
Lifotronic PV-100 Airway Clearance System Analysis Report
Device Identification
The examined images belong to a medical treatment device set. The set consists of a main control unit, air hoses connected to this unit, and a wearable vest. As can be understood from the English phrase on the visual (“Airway Clearance System”), this system is a high-frequency chest wall oscillation device used for clearing airways.
Brand and Model
As a result of detailed examination of both the front face and the rear label of the device, the brand and model information has been definitively identified.
- Brand: Lifotronic
- Model: PV-100 (The “i VEST” logo is also present on the front, but the technical model is specified as PV-100 on the label.)
- Manufacturer: Shenzhen Lifotronic Technology Co., Ltd.
Areas of Use
The product label includes the phrase “Airway Clearance System”. This device is typically used in patients with cystic fibrosis, bronchiectasis, or neuromuscular diseases to help dislodge mucus (phlegm) accumulated in the lungs. The vest is inflated and vibrated at a high frequency, massaging the chest wall and facilitating the opening of the airways.
Quantity Information
A total of 5 main parts and accessories presented as a set have been identified in the visuals:
- 1 Lifotronic PV-100 Main Control Device.
- 1 Gray inflatable therapy vest (with black straps).
- 2 Transparent, spiral-structured air connection hoses.
- 1 Black power cable.
Originality
Upon examining the product’s label printing quality, logo placements, logo prints on the vest, and the device’s molding craftsmanship, the product is assessed to be an Original Lifotronic product.
General Condition
The device and its accessories are visually extremely clean. It is in “like-new” or very lightly used “refurbished” condition. The device’s color retains its vibrant white, with no yellowing observed. The vest and hoses appear clean, as if unused.
Physical Deformation
No breakage, crack, deep scratch, or dent has been detected on the device’s outer casing, corners, or plastic components. No rips or tears are visible in the vest fabric. No signs of crushing or bending have been found on the hoses.
Mechanical Components
The fan grilles on the rear panel are dust-free and clean. The “Emergency Stop” button and the adjustment potentiometer (rotary knob) on the front panel appear physically sound. The plastic clips (buckles) on the vest seem complete and sturdy. The hose input ports on the front of the device are clean and undamaged.
Electronic Components
The device is in the off position in the visuals, therefore no comment can be made regarding the operational status of the screen. However, there are no scratches or impact marks on the screen surface. The green I/O (On/Off) switch, fuse slot, and RS-232 port on the rear panel are physically sound.
Accessories
The vest supplied with the device has two white elbows (connectors) that provide airflow. These connectors have warning labels in English and Chinese stating “Hold the connector when pulling the air flow tube”. There are two hoses to connect the vest and the device, and they have special connection fittings at their ends. The power cable is standard.
Label Information
The data on the technical label located on the back of the device are as follows:
- Production Name: Airway Clearance System
- Model: PV-100
- Power Ratings: a.c. 100-240V, 50/60Hz, 400VA
- SN (Serial Number): P02H00000344 (Indicated next to the barcode)
- Production Date: 2022-07-08 (Next to the factory symbol)
- Expiration/Service Life Date: 2027-07-07 (Next to the hourglass symbol)
Size and Compatibility
While there is no clear indication of the vest’s size (S, M, L, etc.) on the labels, it is estimated to be adult or large child size. Body compatibility may offer flexibility thanks to the adjustable black straps on the vest.
Production Year and Service Life
The device’s label clearly states a production date: July 08, 2022. The date July 07, 2027, indicated by the hourglass symbol, likely points to the recommended service life or maintenance period. Since no counter is visible on the device’s screen, the total operating hours are unknown, but its exterior aesthetics suggest very little use.
Existing Faults and Potential Risks
There are no findings in the visuals indicating that the device is faulty (error light, broken part, disconnected cable). The product appears flawless in terms of physical condition. Cosmetically, it is very close to new, therefore the potential risk of a mechanical fault appears low. Only electronic tests need to be performed.