Secondhand Philips Respironics CoughAssist E70 Cough Assist Device

SKU: MBGU466Y47L
1 views

Ready for Sale

, , , ,

Medbidding Video Check

Matching Service

Price: USD$ 2,000.00 Approx: 100,000.00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 05.11.2026
Report code: 1793861487

Philips Respironics CoughAssist E70 Device Analysis Report

This report has been prepared to list the current status, technical specifications, and hardware components of the medical device based on visual evidence.

Device Identification and Basic Information

  • Device Identification: The images contain a respiratory support device.
  • Brand and Model: Philips Respironics CoughAssist E70
  • Authenticity: The brand logos, label placements, and screen interface in the image are consistent with original product standards.
  • Quantity Information: There is one main device; one carrying case, one silicone breathing tube, one mask, one external adapter or connection part, and one clip component are present.

Usage Areas and Compatibility

  • Usage Areas: The product is a respiratory device that assists in clearing secretions from the airway by providing mechanical cough and aspiration support. It is suitable for clinical or home use in the treatment of patients with neuromuscular diseases and respiratory muscle weakness.
  • Size and Compatibility: No numerical measurement data regarding the physical size of the device is present in the image; however, it is designed to be portable. It is used with compatible standard tube and mask sets.

General Condition and Physical Properties

  • General Condition: The device, along with the accompanying carrying case and accessories, is clean and in good condition.
  • Physical Deformation: No fractures, cracks, dents, or color fading are visible on the device casing, front panel, or screen surface.
  • Mechanical Components: There are no visible issues with the keypad, screen bezel, tube connection ports, or the zipper and strap mechanisms of the carrying case.
  • Electronic Components: The device screen is operational, and the electronic interface illumination is active.

Accessories and Hardware Components

  • Accessories: A gray and black carrying case with Philips Respironics branding, a transparent patient circuit tube, a transparent breathing mask, a connection adapter compatible with the device, and a power cable extending from the rear are present. There is no expiration date information on the accessories in the image.
  • Battery Status: The device’s integrated battery is located inside the housing, and no deformation such as leakage or physical swelling is observed from the exterior.

Label, Text Inventory, and Screen Analysis

  • Label and Text Inventory: The PHILIPS RESPIRONICS text is present on the device body and the bag, the CoughAssist E70 model is on the lower part of the front panel, and the CİHAZ HASTAYA AITTIR (DEVICE BELONGS TO THE PATIENT) statement is on the top of the device. There is no additional data for unreadable areas. These texts indicate the brand, model, and ownership information of the device.
  • Screen Analysis: The screen is on, and the Standby mode text is displayed at the top. At the bottom of the screen, pressure values (-45 cmH2O exhalation, +35 cmH2O inhalation), time settings (3.0 s exhalation, 2.5 s inhalation), and pause time (1.0 s) are shown numerically. These values allow for monitoring the device’s treatment pressure and flow durations.

Production, Documentation, and Usage Duration

  • Production Year: A clear production year cannot be read from the labels and design details in the images; however, the device features current series design lines.
  • Documents: No invoice, warranty certificate, or user manual is present in the images.
  • Usage Duration: No counter information regarding total operating hours is readable on the screen or labels in the image.

Fault and Risk Assessment

  • Current Fault: No broken parts, error codes, severed cables, or missing components were detected in the image.
  • Potential Fault Risk: No concrete risks such as cable crushing, excessive wear on the casing, or rust are observed; the condition of the device is good.