Sold Out

Whatsapp »
SKU: MBTDKIUPX5V

Secondhand Philips HeartStart HS1 AED Defibrillator

Price: USD$ 250,00 Approx: 11.250,00 TL

, , , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 30.12.2025

    Philips HeartStart Defibrillator Analysis Report

    Device Identification

    The examined images belong to a portable automated external defibrillator (AED) device used in emergency medical interventions. The product consists of the main device unit, a red carrying case protecting this unit, a built-in electrode pad cartridge, and one lithium manganese dioxide battery cell. Additionally, there is a pair of scissors inside the case.

    Brand and Model

    As a result of detailed visual inspection on the front of the product and its carrying case, the following information has been identified:

    • Brand: PHILIPS
    • Series/Product Group: HeartStart Defibrillator
    • Spare Part Compatibility: The accessories in the images (M5071A Pad Cartridge and M5070A Battery) technically confirm that the product is a Philips HeartStart OnSite (HS1) or Home Defibrillator model; however, since only “HeartStart” is written on the front of the device, this name has been used throughout the report.

    Originality

    Upon examining the Philips logo, fonts, color tones, and specific accessory part codes (REF numbers) on the product, it is assessed that the product is an original Philips production. The “Smart Pads” cartridge system and the “PULL” lever mechanism reflect the brand’s unique design features.

    Areas of Use

    This device is designed to restore normal heart rhythm by delivering an electric shock to patients experiencing sudden cardiac arrest. It can be used by healthcare professionals, and thanks to its audio and visual prompts, it is also suitable for use by trained first responders or members of the public (in malls, airports, offices, etc.).

    Quantity Information

    The total parts visible in the images are:

    • 1 Philips HeartStart Defibrillator Main Unit
    • 1 Red HeartStart Carrying Case
    • 1 Electrode Pad Cartridge (Attached to the device)
    • 1 Battery (Visible next to the device/inside the case)
    • 1 Blue Scissors (For cutting patient’s clothing)

    General Condition

    The device appears to be cosmetically quite clean and well-preserved. There is no significant wear on the carrying case. No discoloration or yellowing has been observed on the plastic components. Its overall condition indicates careful use or storage on a shelf.

    Physical Deformation

    No cracks, breaks, dents, or deep scratches have been detected on the device’s outer casing. The transparent cover of the “PULL” mechanism is intact. The zipper and stitching of the case appear to be in good condition based on the images. No deformation is observed in the transparent window area on the case either.

    Mechanical Components

    The slot where the pad cartridge sits and the pull lever (“PULL”) appear mechanically sound. The mesh and pockets inside the case are designed to hold the scissors and battery. There is no visual indication of looseness in hinges or connection points.

    Electronic Components and Screen Analysis

    The device does not have an LCD screen; instead, it features a voice command system and LED light warning indicators. In the fourth image, the green “On/Ready” light located at the upper right corner of the device is clearly seen illuminated. This indicates that the device is receiving power and its electronic circuit is active.

    The buttons on the front panel are:

    • Green Button: Device on/off switch (Its active light is illuminated).
    • Orange Button: Shock delivery button with a lightning icon.
    • Blue “i” Button: Information button.

    Battery Status and Label Information

    The blue battery shown in the images has been thoroughly examined:

    • Brand: PHILIPS
    • Part Code (REF): M5070A
    • Date Information: The label states “Install before 2024-07”.

    Analysis Note: The battery’s last installation date is stated as July 2024. As of the report date, this date has passed. The recommended installation period for the battery’s shelf life has expired.

    Accessories and Consumable Material Analysis (Pads)

    The details of the electrode pad cartridge attached to the front of the device are as follows:

    • Type: Smart Pads for Adults (The pictogram in the image is an adult human figure).
    • Compatibility: 55+ lbs / 25+ kg (Suitable for patients weighing 25 kg and above).
    • REF Code: M5071A
    • LOT Number: Y021422-16
    • Expiration Date: The label indicates “2024-08-14” with an hourglass symbol.

    Analysis Note: The expiration date of the pads is August 14, 2024. According to medical device standards, as the conductivity of the pads may decrease over time, the necessity of replacing these parts has been identified based on visual evidence.

    Size and Compatibility

    The device is a compact, handheld model. The “55+ lbs / 25+ kg” marking on the pads indicates that the currently attached equipment should not be used on children (without pediatric pads), but only on adults or children weighing over 25 kg.

    Documents

    Folded papers are visible inside the pocket on the top lid of the case. These are likely quick start guides or operating instructions, but the text on them is not clear enough to be read.

    Potential Failure Risk and Warnings

    No “physical damage that could cause a malfunction” such as breakage or rust on the device is visible in the images. The device’s electronic light is illuminated, indicating that the main unit is operational. However, the most significant risk factor concerns the dates of the consumables:

    • The expiration date of the pads (2024-08-14) has passed.
    • The recommended last installation date for the battery (2024-07) has passed.

    Considering that the device performs a vital function, replacing the battery and pads with new, original ones is the most critical action recommended based on visual data to ensure the device’s reliability.