Ready For Sale
Secondhand Philips Heartstart XL Monitor Defibrillator
Price: USD$ 1.500,00Yaklaşık: 64.500,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 07.08.2025
Philips Heartstart XL Defibrillator Analysis Report
Overview and Device Description
The product shown in the images is a Philips brand Heartstart XL model defibrillator/monitor device. This device is designed to be used both by experienced medical personnel in manual mode and by first responders in Automated External Defibrillator (AED) mode. It performs the functions of monitoring heart rhythm and delivering a controlled electrical shock to the heart in cases of life-threatening cardiac arrhythmias. The overall appearance of the device suggests that it is used but has functional integrity.
Brand and Model Information
The “PHILIPS” brand and “HEARTSTART XL” model name are clearly visible on the device. The quality of the logo and font characters indicates that the product is genuine. The device features manual and AED operation modes, ECG monitoring, and synchronized cardioversion capabilities.
Physical Condition and Deformation Analysis
The overall condition of the device is assessed as used. Its physical state can be summarized as follows:
- Casing: No cracks, fractures, or significant deformations were observed on the blue and white plastic casing. There are minor scratches and slight soiling on the surface, likely from use.
- Screen: As the device is turned off, it was not possible to test whether the screen is operational. However, there are no significant scratches or cracks on the screen surface.
- Mechanical Components: Mechanical parts such as the energy selection knob, other control buttons, and the printer cover appear visually intact. The defibrillation paddles are seated properly in their holders.
- Cables: The coiled paddle cables and the ECG patient cable connected to the device are visually intact. No peeling, crushing, or disconnection has been detected in the cable insulation.
Accessory Evaluation
The following accessories have been identified with the device in the images:
- Main Device Unit: 1 Philips Heartstart XL defibrillator.
- External Defibrillation Paddles: 1 pair (right and left) of adult paddles are integrated into the device.
- ECG Patient Cable: An ECG patient cable with multiple leads is present on the device.
- ECG Paper: A piece of an ECG strip is visible emerging from the device’s printer section, which indicates that there is a paper roll inside.
The AC power cable required for the device’s operation is not visible in the images. This can be considered a potential deficiency.
Technical and Label Information
The device’s screen is off; therefore, no menu, warning, or operating hours information could be analyzed. Labels containing detailed technical information such as the serial number, lot number, or REF code on the device are not readable due to the angle of the photographs taken. Status LEDs such as “AC Power” and “Batt Charger” are present on the front panel, indicating that the device has an internal battery and can operate on mains electricity.
Potential Risk Assessment
The overall physical condition of the device is good. In the visual inspection, no risks requiring immediate attention, such as rust, severe crushing of cables, or cracks in the casing, were observed. Due to the device being turned off, no comment can be made on the current performance status of its electronic components and battery. It is recommended that the buyer has the device undergo calibration and functional tests before use. The absence of the power cable is a condition that could prevent the direct use of the device.