Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 08.06.2026
Report code: 1780940503
ZOLL M Series Defibrillator/Monitor Analysis Report
Device Identification and Brand Information
The product examined in the images is a combination of a defibrillator and a patient monitor. Upon examining the logos and inscriptions on the front panel and the top of the device, it has been clearly identified as the ZOLL M Series model.
Authenticity and General Condition Assessment
Based on the quality of the logo, the placement of the labels, and the general craftsmanship details on the device, the impression is that the product is authentic. The general condition of the device appears to be good. It has been observed to be in a clean and well-maintained state.
Usage Areas
This type of device is of critical importance in emergency medicine, cardiology, and intensive care units. It is used for the treatment of cardiac arrhythmias (defibrillation) and for the continuous monitoring of a patient’s vital signs (electrocardiogram – ECG, oxygen saturation – SpO2). It is designed for life-saving interventions in cases of sudden cardiac arrest.
Quantity Information and Accessories
- One main defibrillator/monitor device.
- Two external defibrillation pads (or electrode connections) with coiled cables.
- One black cable (likely a power or other sensor cable).
- One beige cable (likely an ECG cable).
There are various socket inputs on the sides and front panel of the device. The expiration dates of the accessories are not visible in the images.
Physical and Mechanical Component Inspection
No significant scratches, dents, cracks, discoloration, or heavy dirt have been detected on the device casing. The control buttons, carrying handle, and cable connection points appear to be intact. No broken or loose parts have been observed in the mechanical components.
Electronic Components and Battery Status
The device screen is operational in the first two images and displays information clearly. In the third image, the screen is off. The “CHARGER ON” light is illuminated on the front panel of the device. This suggests that the device has an internal battery and is being charged. The physical condition of the battery (such as swelling or leakage) cannot be determined from the images.
Label Information
The serial number, lot number, REF code, or other technical information on the labels attached to the device are not clearly legible in the images.
Screen Analysis
The device screen provides various information in different operating modes:
- In the first image, the screen displays an “ECG LEAD OFF” warning. This indicates that the ECG electrodes are not connected to the device or are not making proper contact. The SpO2 value is 0%, the ECG gain setting is x1.5, and the heart rate is 0. At the bottom of the screen, “MONITOR” mode and the duration 00:24, along with “Param | Wave 2 | ID# | Alarms |” information, are displayed.
- In the second image, the “ECG LEAD OFF” warning has disappeared, and the ECG waveform and a heart rate of 90 are visible. The SpO2 value is still displayed as 0%. At the bottom of the screen, “MONITOR” mode and the duration 03:44, along with the same parameter information, are present.
- In the third image, the device screen is off.
Size and Compatibility
There is no concrete information regarding the dimensions, size, or user compatibility of the product in the images. However, the general design and carrying handle of the device indicate that it is a portable defibrillator and is suitable for general adult use.
Year of Manufacture and Service Life
There is no concrete information regarding the year of manufacture on the labels or the device itself. The general design and physical condition of the device point to a modern but not brand-new production period. Total usage hours are not visible on the screen or labels of the device.
Existing and Potential Failure Risks
No clear evidence of failure, such as broken parts, error messages (ECG LEAD OFF is a warning, not a failure), severed cables, or missing components, has been detected in the images. The general condition of the device appears to be good. No conditions that could pose a potential failure risk, such as severe wear, rust, or cable crushing, have been observed.