Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 10.11.2026
Report code: 1794320042
Insighters Video Laryngoscope Analysis Report
Device Identification and Basic Information
The product in the images is a portable video laryngoscope system designed to examine the upper airway during intubation procedures and to facilitate the placement of the breathing tube. The product is housed in a protective gray hard carrying case.
Brand and Model
According to the label and text inventory on the device body and blade components, the brand of the product is Insighters, while the model information cannot be clearly read from the image. The main body and screen unit components belonging to the device series are present.
Authenticity
Upon examination of the screen quality, logo placement, part molds, and the internal foam layout of the carrying case, it is observed that the product is authentic.
Usage Areas
It is used to visualize the upper airway during routine or difficult intubation applications in emergency departments, operating rooms, and intensive care units. The transparent blades, which are accessories of the product, provide intubation support suitable for the patient’s anatomical structure.
Quantity Information
The images show 1 main screen unit, 1 laryngoscope handle, 2 transparent spare laryngoscope blades, 1 power adapter, 1 connection cable, and 1 protective carrying case.
General Condition
The device and its accessories are in new and unused condition. They are stored in an orderly manner within the custom-cut black foam beds inside the protective case.
Physical Deformation
There are no scratches, dents, cracks, discoloration, dirt, or dust accumulation on the device body, screen surface, or plastic components.
Mechanical Components
There are no visible issues with the locking mechanisms of the screen unit, laryngoscope handle, or carrying case; the parts are in place and secure.
Electronic Components
The device screen is in the off position in the image. No breakage or crushing is observed on the electronic connection sockets and the power adapter cable.
Accessories
Inside the carrying case, there is 1 power adapter, the main body attached to the laryngoscope handle, and 2 transparent laryngoscope blades located in a separate compartment. There are external socket inputs on the device. There is no information regarding an expiration date on the accessories.
Battery Status
The device has an internal battery; however, when viewed from the outside, there is no visual clue or sign of swelling regarding the battery capacity or its cellular condition.
Label and Text Inventory
There is a brand logo and various guide texts on the laryngoscope blade and handle. There is no data for the unreadable areas. The brand and model markings on the label allow the buyer to identify the manufacturer of the device.
Screen Analysis
The device screen is in the off position, and no menu or warning text is visible on the screen.
Size and Compatibility
Although size or dimension information is not present in the image, the product has standard clinical usage compatibility due to its product type and blade structure.
Production Year
There is no concrete indication of the production year on the labels or documents; the design and physical condition of the device indicate that it belongs to a current period.
Documents
There are no written documents such as invoices, warranty certificates, or user manuals in the images.
Usage Duration
Since the device screen is off and there is no counter on the labels indicating operating hours, there is no information available regarding the usage duration.
Existing Faults
No broken parts, error messages, broken cables, or missing components were detected in the images.
Potential Fault Risk
No concrete risks such as severe wear, rust, or cable crushing were detected in the images; the condition is very good.