Secondhand Ion Ezview 90D P-IOV-003 Indirect Ophthalmoscope Lens

, , , ,

Price: USD$ 95,00 Approx: 4.275,00 TL

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 02.12.2025

ION Vision ezView 90D Ophthalmic Lens and Carrying Case Analysis Report

Device Identification and Product Description

The product shown in the visuals is a diagnostic lens with high refractive power, used for examination purposes in the field of ophthalmology (eye health and diseases). The product is stored in its special protective case. The primary function of the product is to perform a non-contact examination of the patient’s fundus (retina) using a biomicroscope (slit lamp).

Brand and Model Information

As a result of detailed examinations, the brand and model of the product have been clearly identified. The inscriptions on the box and the lens rim are as follows:

  • Brand: ION (The inscription “ion” is clearly visible within the stylized eye-shaped logo on the box.)
  • Model: ezView 90D (The inscriptions “EZVIEW” and “90D” are on the box, and “90D” is on the lens rim.)

The product is a 90 Diopter lens, manufactured by “ION Vision,” and is considered standard for ophthalmic examinations.

General Condition and Cosmetic State

The condition of the product and its carrying case should be evaluated under two separate headings, as there is a significant difference in condition between the lens and the case:

1. Carrying Case:

The outer surface of the case has undergone significant physical deformation. There are extensive peelings, cracks, and flaking in the black coating material. The faux leather/coating material, especially on the edges and top surface of the case, appears to have reached the end of its lifespan. The red velvet/fabric lining on the inside appears relatively cleaner, but it is likely that pieces from the outer coating have entered the interior compartment.

2. Lens:

The lens itself is in a better condition compared to the case. The white technical inscriptions (LOT, 90D, etc.) on the black metal rim are legible. No deep cracks or breaks are visible on the glass (optical) surface that could be detected from the visual. However, given the sensitivity of the lens surface, the possibility of dust accumulation or micro-scratches caused by debris from the case should not be overlooked.

Areas of Use

This product is used in professional healthcare facilities and ophthalmologists’ offices for the following purposes:

  • General fundus examination in conjunction with a slit lamp (biomicroscope).
  • Detailed visualization of the posterior pole of the eye.
  • Retina examination even with a small pupil opening.

Labels and Technical Markings

The technical markings identified on the product and its case are as follows:

  • EZVIEW: Indicates the product’s model series.
  • 90D: Expresses the optical refractive power of the lens (90 Diopter). This value determines the magnification ratio and field of view characteristics of the lens.
  • Logo: The word “ion” within an eye pupil (belongs to the ION Vision brand).
  • Rim Markings: The metal rim of the lens features the inscription “LOT” (Lot Number) and other technical codes. Due to the angle in the visual, the full continuation of the serial number cannot be clearly read, but its presence has been confirmed.

Authenticity Assessment

The print quality on the box, the logo design, and the laser etching details on the lens rim indicate that the product is an original ION Vision production. Aftermarket products typically do not feature this type of distinctive box design and detailed rim labeling.

Potential Risk and Malfunction Assessment

No critical damage (such as broken or cracked glass, etc.) visually apparent in the functional part of the product (the lens) has been observed. However, the following points should be noted:

  • Risk of Cosmetic Deformation: The extensive peeling on the outer surface of the case may cause detached particles to adhere to the lens. This situation could affect sterility and optical clarity.
  • Hygiene: Due to the condition of the case, the lens should undergo professional cleaning before use. Debris from the outer coating could lead to undesirable particulate contamination in the examination environment.

Quantity Information

The analyzed visuals show a total of 1 unit of a 90D lens and 1 original carrying case. No other accessories, documents, or parts are present in the visuals.