Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 10.06.2026
Report code: 1781078570

SERVONA Digital Speech Aid Analysis Report

Identification of Device and Accessories

The images show a speech aid device designed for individuals with speech difficulties and various accessories belonging to this device. The main device has a metallic gray body with light blue top and bottom covers. Next to the device, there is a carrying case featuring the brand’s logo. Additionally, rechargeable batteries, a battery charger, a charging adapter, and oral tubes with an adapter used with the device are present in the images.

Brand and Model Information

  • Speech Aid Device Brand-Model: SERVONA Digital Speech Aid
  • Carrying Case Brand: SERVONA
  • Battery Charger Brand: VARTA
  • Charging Adapter Brand: KWMOBILE
  • Batteries Brand: VARTA

The word “digital” is clearly visible on the device itself, and the “SERVONA” logo is visible on the carrying case. The document accompanying the product contains the phrases “SERVONA Mundrohr mit Adapter” and “SERVONA Digital Speech Aid.” The “VARTA” brand is clearly legible on the battery charger, and the “kwmobile” brand is clearly legible on the charging adapter. The “VARTA” brand is also present on the batteries.

Authenticity Assessment

The general appearance of the device and accessories in the images, the quality of the labels and logos, and the craftsmanship details suggest that the product is authentic. In particular, the presence of the SERVONA-branded document and the professional printing on it support the authenticity of the product.

Usage Areas

This device is a speech aid designed to assist in voice production for individuals who have speech difficulties or have lost their vocal cords. As stated in the document, the “SERVONA® digital Speech Aid” is used in conjunction with an intraoral connector and adapter to create sound vibrations in the mouth and throat area. This helps users regain or improve their speaking abilities. The device is a suitable medical product, especially for post-laryngectomy patients or individuals with voice disorders. The oral tubes and adapter allow the device to be placed inside the mouth to transmit sound.

Quantity Information

  • SERVONA Digital Speech Aid: 1 piece
  • SERVONA Carrying Case: 1 piece
  • VARTA Battery Charger: 1 piece
  • VARTA AA Rechargeable Battery: 4 pieces
  • KWMOBILE Charging Adapter: 1 piece
  • Oral Tube: 4 pieces (in plastic packaging)
  • Oral Tube Adapter: 1 piece (in plastic packaging)

General Status and Condition

The general condition of the device and accessories appears to be good. The metallic body and plastic parts of the main device are clean. The carrying case shows no signs of wear. The batteries are placed in the charger and appear as new. The oral tubes and adapters are in their original packaging and are unused.

Physical Deformations

No significant physical deformations such as scratches, dents, cracks, color fading, or dirt/dust have been detected on the device’s casing, buttons, or other parts in the images. The surfaces of the products appear shiny and clean.

Mechanical Component Inspection

The two blue buttons on the device appear sturdy. The top and bottom covers fit properly onto the body. The stitching and closing mechanism of the carrying case appear to be in good working order. The battery slots of the battery charger and the plug part of the charging adapter show no signs of mechanical issues.

Electronic Component Inspection

The internal electronic components of the device are not visible in the images. However, the VARTA brand battery charger and the KWMOBILE brand charging adapter form a complete charging set with the batteries. These components show no signs of electronic failure when viewed from the outside.

Condition of Accessories

The device comes with one SERVONA-branded carrying case, one VARTA brand battery charger, four VARTA brand AA rechargeable batteries, and one KWMOBILE brand charging adapter. Additionally, there are four oral tubes and one adapter in their original packaging. A lanyard is seen attached to the top of the device. All accessories are complete and in good condition. The oral tubes and adapters are medical products intended for single use or a specific duration of use, and their packaging has not been opened. The document contains the information: “The tube can be used up to 30 days.”

Battery Status

It is not clear from the images whether the device has an internal battery. However, there are four external VARTA brand AA rechargeable batteries, a VARTA brand charger to charge these batteries, and a KWMOBILE brand charging adapter. The batteries show no physical deformation such as swelling or leakage.

Label Information and Meanings

  • REF Code: 18253 – The REF code indicates the reference number of the product. This code is used for product identification, ordering, and inventory tracking. The document states that it belongs to the “SERVONA Mundrohr mit Adapter” product.
  • CE Mark: CE0197 – The CE mark indicates that the product complies with the European Union’s health, safety, and environmental protection standards. “0197” is the identification number of the notified body that assessed the product’s conformity. This means the product can circulate freely in the European market.
  • Other Symbols: Crossed-out wheeled bin symbol and “i” symbol. – The crossed-out wheeled bin symbol indicates that the product should not be disposed of with household waste and must be collected separately and recycled as electronic waste. The “i” symbol indicates that the user should refer to important information or the user manual regarding the product.

Screen Analysis

There is no screen on the device. Therefore, no analysis can be made regarding text, warnings, or values on a screen.

Dimensions and Compatibility

The exact dimensions of the device or accessories are not specified in the images. However, it is understood that the device has a cylindrical structure that can be held in the hand and that the oral tubes are of a size suitable for human oral structure. The information “1 Adapter / 1 Adapter” and “4 Mundrohre / 4 Oral Tubes” in the document shows that the product is compatible with these accessories. It is stated that the oral tubes can be used for up to 30 days.

Year of Manufacture

There is no direct year of manufacture label on the product. However, the phrase “18253 Version 2019-05-23” appears in the bottom right corner of the document that comes with the product. While this date indicates the printing or revision date of the document, it offers a concrete clue that the product was manufactured on or near this date. Therefore, it can be interpreted that the product was manufactured in 2019 or later.

Documents

The images include a user and promotional document titled “SERVONA Mundrohr mit Adapter,” which contains explanations in German and English. This document includes important information such as how to use the device, cleaning of the oral tubes, and usage duration. Additionally, the contact information for Servona GmbH is included in the document. This document provides all the necessary instructions for the buyer to use the product correctly and safely.

Usage Duration

There is no information regarding the total usage hours or duration on the device’s screen, label, or documents. However, it is stated in the document that the oral tubes can be used for up to 30 days.

Existing Faults

No clear evidence of any faults such as broken parts, error messages, frayed cables, or missing components has been detected on the device or its accessories in the images. All parts appear intact and functional.

Potential Risk of Failure

No potential risk of failure such as severe wear, rust, or cable crushing has been observed in the images. The general condition of the device and accessories is good, and there are no risk factors present.