Approved

Ready For Sale

Whatsapp »
SKU: MBQRCJ7LZE5

Secondhand Berchtold Elektrotom 640 Electrocautery Machine

Price: USD$ 1.500,00 Approx: 66.000,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 02.12.2025

      Berchtold ELEKTROTOM 640 Electrosurgery Device Analysis Report

      Device Identification and Brand Information

      The product in the image is an industrial-grade electrosurgery unit used for tissue cutting (electrotomy) and bleeding control (coagulation) procedures in surgical operations. It is often referred to as a cautery device.

      • Brand: BERCHTOLD
      • Model: ELEKTROTOM 640
      • Product Type: Electrosurgery (Cautery) Unit

      Areas of Use

      This device is used in operating room environments in general surgery, orthopedics, urology, and similar branches. It is designed to cut tissue or seal bleeding vessels (coagulation) using electric current. The device in the image is a professional model that offers multiple output channels, allowing the simultaneous use of different surgical hand instruments.

      General Condition and Authenticity

      The device is in used condition. The logo, font styles, and control panel layout indicate that the product is an original BERCHTOLD device. The device is placed within a shelved transport system (cautery stand or medical tower). The overall appearance of the device proves that it has been in active service for a long time and bears signs of intensive use.

      Physical Deformation and Cosmetic Examination

      There are some notable details on the product’s casing and front panel:

      • Casing Integrity: No prominent dents or large cracks are visible on the metal outer casing. Although the side surfaces are not fully visible due to its position on the shelf, the front facade appears intact.
      • Manual Markings: Handwritten markings made with a marker pen (black marker) are present on the front panel. An “X” mark has been placed over a mode in the “ELECTROTOMIE” section and over some symbols in the “COAGULATION 1” and “COAGULATION 2” sections. Additionally, the number “50” has been handwritten next to the first coagulation display. This situation suggests that certain functions of the device might be faulty or that specific settings are marked by the user to be avoided.
      • Dirt and Stains: Dirt buildup around the buttons and on the panel surface is present, accumulated over time.

      Technical Interface and Electronic Components

      The device’s front panel is divided into three main technical sections, and the following details can be observed from the image:

      • Electrotomy (Cutting): This section on the left contains a yellow adjustment knob, “SET”, “MICRO” buttons, and LED indicators showing cutting modes.
      • Coagulation 1 (Cauterization): Located in the middle section, this part includes a digital display (currently off), a maximum wattage adjustment bar, an “AUTO” button, and a blue adjustment knob.
      • Coagulation 2: This is the second independent cauterization channel located on the right. Similarly, it features a digital screen, an adjustment bar, and a blue control knob.
      • Memo and Mode: On the far right, there are memory (MEMO 1-4) buttons and indicators for mode selection (MONO, BI, TRI).
      • Socket Inputs: At the bottom of the device, there are neutral electrode (plate) input, monopolar handpiece inputs, and bipolar output sockets. The physical integrity of the sockets is preserved.

      Accessories and Connections

      The accessory and connection details identified in the image are as follows:

      • Cables: A grey cable is attached to the bottom right socket on the front panel of the device, likely leading to bipolar forceps or a similar instrument.
      • Bottom Shelf Content: On the shelf below the device, there are numerous tangled grey cables (likely footswitches or power cables). Additionally, another electronic medical device with a partial “lator II” inscription is visible on the bottom shelf, but the focus is on the Berchtold cautery device.
      • Top Section: A laminated instruction manual or warning sign is visible, tucked between the shelf and the top of the device.

      Quantity Information

      The image shows 1 unit of the Berchtold Elektrotom 640 main unit. The associated cable bundles should be considered as a single set.

      Potential Malfunction Risk and Warnings

      The most critical observation regarding the device is the handwritten “X” marks on the panel. In medical devices, users typically mark non-functional, faulty, or modes that should not be used in this manner. This situation:

      • Suggests that the marked cutting and coagulation modes may be faulty,
      • Presents the risk that the device is not fully functional and only operates in certain modes (those not marked).
      • The “50” inscription may have been written to indicate a calibration error or to remind the user of a fixed value to be used for that specific mode.

      The device does not appear to be connected to power, and its screens are off, therefore it cannot be visually confirmed whether it powers on electronically.