Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 23.10.2025
BTL TENS 3 Electrotherapy Device Analysis Report
Overview and Device Identification
The visuals show an electrotherapy device and its accessories used for pain management and muscle stimulation in the fields of physiotherapy and health. As a result of the examinations, the brand of the device has been clearly identified as BTL, and the model as TENS 3. The product is presented with its original box, carrying bag, and various application accessories. It is seen on the box that the device belongs to the “TENS range” series and is promoted with the slogan “For Physiotherapy and Health”.
Usage Status and Condition
The device and its accessories are generally in used condition. The product’s box shows noticeable wear, dents, and tears on the edges. This situation indicates that the product has been stored or transported for a long time. Although the device itself is generally in good condition, slight signs of use can be seen on the screen area and casing. Among the accessories, color changes and usage-related dirt on the electrode pads are particularly noticeable. However, no major crack, break, or deformation that would hinder its operation is observed on the device.
Physical Deformation and Mechanical Components
Upon examining the physical condition of the product, the following details have been identified:
- Device Casing: There are no noticeable cracks or breaks on the silver-colored casing. The icons and texts on the keypad are legible, and there is no fading.
- Screen: The device’s screen is off. There may be slight superficial scratches on the screen surface or wear on the protective film, but no deep scratch or crack is visible.
- Box: The corners and edges of the original cardboard box have significant dents, wear, and small tears.
- Electrode Pads: It is clearly seen that the pads in the visuals are used, and there is yellowing and dirt accumulation on their surfaces.
Accessories and Quantity Information
The following components have been identified in the box contents:
- 1 BTL TENS 3 main device
- 1 original packaging box
- Numerous yellow and blue electrode cables
- Numerous used electrode pads
- 1 black power adapter/charger
- 1 black fabric carrying bag
- 2 elastic bandages/fastening straps
It is not clearly understood from the visuals whether there is a missing part in the device, but the main components required for basic use are present. The device’s battery is internal, and the phrase “rechargeable batteries” is located on the box. There is no visual evidence regarding the current health status of the battery.
Label Information and Technical Specifications
According to the label and information on the product box, some technical specifications of the device are as follows:
- Number of Channels: 4 independent channels.
- Frequency: 0.3-150 Hz
- Pulse Width: 30-1000 µs
- Power: 120 mA per channel
- Power Source: Rechargeable batteries.
- Barcode (EAN Code – for TENS 3): 8032625826095
- Certification: CE 0476 mark is present.
On the back of the box, there is information that the manufacturer is Domino S.R.L. and its distributor in Turkey is BTL Medikal Cihazlar.
Potential Malfunction Risk and Evaluation
No obvious malfunction or damage (broken part, error message, etc.) related to the device is seen in the visuals. The overall physical condition of the device appears well-preserved. However, as a potential risk, the wear and dirtiness of the electrode pads due to use may cause a decrease in performance in terms of hygiene and conductivity. These pads may need to be replaced before use. Based on visual analyses, the device itself gives the impression of having a low risk of functional problems and resembles a well-maintained product.