Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 26.11.2026
Report code: 1795680722
Karl Storz Image1 S Endoscopy Imaging Unit Analysis Report
Device Identification and Basic Information
The images show two medical imaging units stacked on top of each other. These units are used in endoscopic surgery and imaging procedures.
- Brand and Model: Storz Karl Storz-Endoskope image1 S
- Device Type: Endoscopy Imaging Unit
- Quantity Information: There are 2 main unit modules positioned one above the other.
- Authenticity: The device appears to be authentic due to the original logos, type labels, typography, and industrial design quality present on the units.
Areas of Use
The device is used in operating rooms and endoscopy units to process images from endoscopic cameras and transmit them to a display during minimally invasive surgical operations.
General Condition and Physical Deformation
The general condition of the devices is used. There is slight discoloration and surface staining on the metal and plastic outer casings, and yellow warning labels are present on the right side. No fractures or deep cracks are observed on the casings.
Mechanical and Electronic Components
The connection slots, USB ports, power button, and module coupling mechanisms on the front panel are physically in place. The green status LED on the front panel, which indicates whether the electronic circuits are operational, is active.
Accessories and Connection Points
There are no external cables, power cords, controllers, or additional accessories in the image. The front panel features two USB connection ports and a dedicated camera connection slot.
Battery and Power Status
The devices do not contain an internal battery; they operate directly via mains electricity.
Label and Text Inventory
The text read on the front panels and bodies of the units is as follows:
- On the upper unit front panel: The text IMAGE1 S X-LINK, a green status LED light, a wide black connection slot in the center, an HD icon in the top right corner, and the TC 301 model in the bottom right corner. Additionally, there is a yellow label with the number 4 on the right edge.
- On the lower unit front panel: The STORZ KARL STORZ-ENDOSKOPE logo, a power on/off icon, and the text IMAGE1 S CONNECT are located on the top left. Menu icons, two USB ports, an S letter inside a square in the top right corner, and the TC 200 model in the bottom right corner are present in the center. There is a yellow label with the number 4 on the right edge.
These texts and codes allow for the verification of the device models, serial connection units, and manufacturer identity.
Display Analysis
There is no integrated screen on the devices; images are transmitted to an external medical monitor.
Dimensions and Compatibility
Numerical measurements regarding the device dimensions are not provided in the image. The dimensions are compatible with standard 19-inch rack-type medical device consoles.
Year of Manufacture
There is no clear information regarding the year of manufacture on the labels in the images. The design and outer casing structure of the device indicate that it complies with professional medical device manufacturing standards.
Documents
There are no invoices, warranty certificates, user manuals, or similar written documents in the images.
Usage Duration
There is no counter information on the screens or external labels of the devices indicating the total operating hours.
Existing Faults and Potential Risk of Failure
There is no evidence of existing faults such as broken cables, broken parts, or error messages in the images. No rust or dents have been observed on the outer casing, and the general condition is clean.