Ready For Sale
Secondhand Karl Storz Telecam SL Pal 202120 20 Endoscopy System
Price: USD$ 2.750,00 Approx: 121.000,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 16.12.2025
Karl Storz Telecam SL pal Endoscopic Camera Control Unit Analysis Report
Device Identification, Brand and Model Information
As a result of detailed visual inspections, the analyzed device has been identified as an endoscopic camera control unit (CCU) used in medical imaging systems, along with an associated camera head. The brand and model information of the device is clearly and unmistakably present on the product’s front panel.
- Brand: KARL STORZ
- Product Series: Telecam SL
- Model/Video Format: Telecam SL pal (indicates it has PAL video standard)
- Device Reference (REF) Code: 202120 20 (clearly stated on the right side of the front panel)
The camera head and cable displayed with the device also belong to the same brand. The logos “KARL STORZ – ENDOSKOPE” and “STORZ” are clearly legible on the camera head.
Areas of Use and Authenticity Assessment
This device is used for image processing during endoscopy and laparoscopy procedures in professional medical environments (hospitals, clinics). It is the main processing unit that converts optical data coming from the tip of the endoscope into a digital signal via the camera head and transmits it to the monitor.
The font types of the logos on the device, the material quality, and the language and placement of the warning labels, which comply with professional medical standards (Hospital Grade, Class I equipment, etc.), unequivocally indicate that the product is an Original Karl Storz production. The labeling and casing workmanship are up to industrial standards.
Quantity and Component Information
The system analyzed in the visuals consists of a total of 2 main parts:
- 1 Unit Karl Storz Telecam SL pal Camera Control Unit (Main Console)
- 1 Unit Karl Storz Endoscopic Camera Head and Integrated Cable
General Condition and Cosmetic Inspection
The product is in “used” condition. While the general structure of the device appears sound, there are aesthetic details that reveal its age.
- Casing Structure: Slight yellowing is observed in the paint of the metal casing, indicating that the device has been in use for a certain period. No prominent dents or major impact marks are visible on the edges of the top cover.
- Front Panel Label: On the purple model and brand strip on the front face of the device, especially in the left corner, there are slight liftings or deformations due to adhesive weakening. However, the text remains fully legible.
- Keypad and Buttons: The power switch (I/O) and white balance button on the front panel are mechanically in place. The lower drawer mechanism labeled “PULL” appears robust.
Technical and Electronic Components Analysis
Although electronic functionality cannot be fully tested via visuals, the physical indicators are as follows:
- Power Switch: The green illuminated rocker-type power switch located on the left side of the front panel is physically intact.
- Connection Ports: The camera input socket located on the right side appears clean. No visible oxidation or bending of the pins is externally noticeable.
- Camera Head: The black camera head and its cable are generally in clean condition. The mechanical integrity of the focus ring is preserved. No prominent kinks, peeling, or outer sheath damage are noticeable on the cable.
Labels and Warning Signs
The safety warnings and labels located on the top cover of the device are legible. These texts contain the following information:
- Safety Warnings: The standard warning text starting with “Grounding reliability can only be achieved…” is present, stating that the device’s grounding safety can only be ensured with “Hospital Grade” receptacles.
- Explosion Risk Warning: The warning “DANGER – Possible explosion hazard” is present, indicating that it should not be used in environments with flammable anesthetics.
- Symbols: The front panel features symbols indicating BF Type protection class (square with a human figure) and equipotential bonding symbols.
Dimensions and Estimated Manufacturing Year
The device is sized appropriately for a standard medical “rack” system or desktop use (estimated 30-35 cm width). Although a clear Date of Manufacture label is not visible in the visuals, the design language and color scheme of the “Telecam SL” series suggest that the device belongs to an earlier generation of technology (close to the analog/SD era). However, the REF code 202120 20 is a recognized model of this series.
Potential Risk and Malfunction Assessment
As a result of the visual analysis, no critical breakage, burn marks, or missing parts that would prevent the device from operating were detected. However, considering the device’s age and used condition, the following points should be taken into account:
The connection points of the cables and the optical input of the camera head are the most sensitive areas; however, these parts appear clean in the photos. There are no signs of rust on the device’s casing or connection points. The instruction manual card or mechanism under the “PULL” tray is also in place. The overall condition suggests that the device is clean enough to be considered functional in the second-hand market.