Approved

Ready For Sale

Whatsapp »
SKU: MB9US62DPOY

Secondhand Karl Storz Telecam SL Pal 202120 20 Endoscopy System

Price: USD$ 2.750,00 Approx: 121.000,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 16.12.2025

      KARL STORZ Telecam SL pal Endoscopy Camera System Analysis Report

      Device Identification

      As a result of the analysis performed on the visuals, the product has been identified as a medical endoscopy camera control unit (CCU) and a connected endoscopy camera head. The system consists of two main parts: the processor console unit and the wired camera head.

      Brand and Model

      The logos and model inscriptions on the product are clearly legible. Accordingly:

      • Brand: KARL STORZ – ENDOSKOPE
      • Main Device Model: Telecam SL pal
      • Main Device REF Code: 202120 20
      • Camera Head Model (REF): 20200042
      • Camera Head Brand: KARL STORZ

      Areas of Use

      This device is part of an endoscopic imaging system used in medical procedures (surgeries and diagnostic operations). It is designed to process the image coming from the endoscope tip and transmit it to a monitor. It is suitable for use in hospital departments such as surgery, gastroenterology, ENT, and urology. The system operates in “PAL” video format.

      Originality

      The device’s front panel, typography, material quality, and labeling standards on the rear/top (design language specific to the KARL STORZ brand) indicate that the product is an original KARL STORZ product. Logo prints and color tones are consistent with the brand’s corporate identity.

      Quantity Information

      A total of 2 product parts are visible in the images:

      • 1 unit Camera Control Unit (Main Console)
      • 1 unit Wired Camera Head

      General Condition

      From an external perspective, the product appears clean and in a well-preserved condition. Although it is a second-hand item, it gives the impression of having been used carefully in a laboratory or hospital environment. There is no significant heavy damage or wear visible.

      Physical Deformation

      No significant dent, crack, or break has been detected on the main unit’s metal/plastic casing. The corners and edges are smooth. There is also no visible crack or deformation on the camera head’s body.

      Mechanical Components

      The “On/Off” button on the front panel appears physically intact. The information card drawer labeled “Pull” located under the panel is in place. The camera head connection socket appears robust, and no bending in its pins or frame is discernible in the visuals.

      Accessories

      The main power cable or video output cables are not visible with the device. Only the camera head (Head) and its integrated cable, which enables system-specific image acquisition, are present. The connection integrity between the camera cable’s input socket to the main unit and the camera head is complete.

      Electronic Components and Camera Head

      There are two blue buttons on the camera head (likely for function/white balance settings). The buttons are in place and intact. A metal focusing or connection ring (coupler adapter) is visible on the head part.

      Labels and Technical Information

      The information located on the top part and front panel of the device is as follows:

      • Top Panel Warnings: It is stated that grounding safety will be ensured with “Hospital Grade” outlets suitable for hospital use. Additionally, a warning for explosion risk in environments with anesthetic gases (Danger – Possible Explosion Hazard) is present in English and French.
      • Camera Head Serial/Lot Information: On the metal ring of the camera head, a code “GIA012130” (probable serial number) and a part code “20200042” (REF) are legible.

      Battery Status

      This device is a fixed unit that operates with mains electricity (AC). There is no indication of an internal battery in the visuals or the device’s structure. It operates with an external power cable.

      Potential Malfunction Risk

      During the visual inspection, no serious risk factors such as breakage, burn marks, heavy corrosion, or cable disconnection that would impede the device’s operation are observed. The product’s condition suggests it has the potential to operate when proper power and monitor connections are made. No crushing or stripping is visible on the cables.