Secondhand Karl Storz Telecam SL Pal 202120 20 Endoscopy System

SKU: MBFQI92W51M
1 views

Ready for Sale

, , , ,

Medbidding Technical Expertise

Secure Payment System

Price: USD$ 1,750.00 Approx: 87,500.00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 26.11.2026
Report code: 1795680003

Karl Storz Telecam SL Pal Endoscope Device Analysis Report

Device Identification and Basic Information

Upon examination of the main device and accessories shown in the images, it is observed to be an endoscopic camera system used for medical imaging purposes. The system consists of a main control unit and a camera head with a cable connected to this unit. The device enables the visualization of internal organs and cavities during medical and surgical operations.

Brand and Model Information

The logos and inscriptions on the front panel of the main device have been examined. The brand name is read as Storz, and the model name as telecam SL pal. The model code is indicated as 202120 20. The serial number SN LF621450-H is located on the camera head. On the front surface of the other device seen in the upper left, the xenon nova 300 model and the code 201340 20 are present.

Quantity Information

The images show a total of one main control unit and one camera head, along with the cable and connector group belonging to this head.

Authenticity and General Condition

The outer casing of the device, the label placement, and the panel quality exhibit an original structure consistent with manufacturer standards. The device is in used condition, and there is slight dust and marks on the outer surface.

Physical Deformation and Mechanical Components

No fractures or cracks are observed in the plastic and metal components of the main unit. The power switch, socket inputs, and pull handles on the front panel are in place. There are slight stains and marks on the top cover surface due to usage.

Electronic Components and Battery Status

The front panel of the device features a power switch, warning symbols, and connection ports. The device operates with external mains electricity and does not contain an internal battery.

Accessories and Connection Ports

There is a camera head with a black cable assembly on the top of the main device. A black multi-pin connection socket is located on the bottom right corner of the front panel. On the bottom left corner, there is a green illuminated power switch.

Label and Inscription Inventory

There are warning texts on the top panel of the main unit. These texts include DANGER – POSSIBLE HAZARD IF USED IN THE PRESENCE OF FLAMMABLE ANESTHETICS, CAUTION – RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER, and CAUTION – REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. These warnings indicate the danger of use in the presence of flammable anesthetic substances and the necessity of not opening the cover against the risk of electric shock. The inscriptions STORZ KARL STORZ ENDOSKOPE, telecam SL pal, and 202120 20 are present on the front panel.

Screen Analysis

The main device examined in the images does not have an active screen; the device is designed as a control and image processing unit.

Dimensions and Compatibility

There is no numerical measurement information regarding the physical dimensions or weight of the device in the images. The product is designed to work in compatibility with medical endoscopy systems.

Year of Manufacture

When the labels, fonts, and device design in the images are examined, there is no direct indication of a year of manufacture. The design details of the device reflect professional medical equipment standards from a past period.

Documents and Usage Duration

There is no invoice, warranty certificate, user manual, or any counter data showing the usage duration in the images.

Existing Faults and Potential Risk of Failure

There is no clear evidence of a fault such as a broken part, severed cable, or error message in the images that would prevent the device from operating. No concrete risk such as crushing of cables or corrosion is observed; its general condition is orderly.

Areas of Use

This device is used in operating rooms of hospitals and clinics to enable the transfer of internal body images to a screen during minimally invasive surgical procedures such as laparoscopy, endoscopy, and arthroscopy.