Sold Out

Whatsapp »
SKU: MBKP7KI789D

Secondhand Storz Telecam SL Pal 202120 20 Endoscopy System

Price: USD$ 3.500,00 Approx: 154.000,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 28.11.2025

    KARL STORZ Telecam SL pal and Camera Head Analysis Report

    Device Identification

    The main product in the visuals is a professional camera control unit (CCU) used in medical endoscopy systems. An endoscopy camera head and its connected cable, positioned to connect to the system, are also present on the unit. This device is a video processor designed for endoscopic surgery and imaging procedures.

    Brand and Model

    As a result of detailed examination, the brand and model information of the device have been identified as follows:

    • Brand: KARL STORZ
    • Model: Telecam SL pal
    • Reference Number: 202120 20 (Located on the upper right corner of the front panel)
    • Serial Number: DF610343-P (Located on the rear label)

    Authenticity

    The print quality of the logos on the device, the industrially standard port arrangement, the font structure of the “Karl Storz – Endoskope” inscription, and the safety certification labels such as CSA/UL (Medical Equipment Classified by Underwriters Laboratories) on the rear panel indicate that the product is an original Karl Storz product.

    Areas of Use

    This device is designed for use in medical environments, particularly in operating rooms and endoscopy suites. It enables the transfer of internal body images to a monitor via endoscopes (optics) attached to the tip of the camera head. It is used as an imaging unit in closed surgeries across various specialties such as general surgery, urology, ENT, and gynecology.

    Quantity Information

    A total of 2 main parts are visible in the images:

    • 1 Unit Karl Storz Telecam SL pal Camera Control Unit (Housing)
    • 1 Unit Camera Head and Integrated Cable (Resting on the housing)

    General Condition and Physical Deformations

    The device is a used product and shows cosmetic signs consistent with its age:

    • Slight dirt or marks are visible on the top surface of the device’s metal casing, but no deep scratches or dents have been detected.
    • The front panel’s plastic frame generally appears clean. No significant cracks are observed in the gray and navy blue sections.
    • A blue tape or label-like wrapping is noticeable on the connector part of the camera head placed on the unit. This may suggest that a procedure was previously performed on the connector area or that a distinguishing mark was placed there.
    • Warning texts (DANGER, CAUTION, etc.) on the device are legible; there is no fading.

    Mechanical and Electronic Components

    Based on the visual inspection, the mechanical and electronic details are as follows:

    • Front Panel: The “0-I” position power switch (rocker switch) on the left side appears physically sound. The white balance button and function key are present in the middle. The camera input socket on the right side seems mechanically intact.
    • Rear Panel: All socket inputs (BNC, S-Video, DIN) on the rear panel are in place. No corrosion or rust is visible on the metal connectors, although some natural dulling due to use may be present.
    • Ventilation: The device’s housing structure is closed; no issues like blocked air vents are discernible on visible surfaces.

    Accessories and Connection Ports

    The product in the visual includes a camera head as an internal accessory, but the power cord is not present in the image. The rich connection options on the rear panel are as follows:

    • Video Outputs (OUTPUTS): 5 BNC connectors (RED, GREEN, BLUE, SYNC, and likely COMP Video).
    • S-Video: 2 4-pin S-VIDEO outputs.
    • ACC Outputs: 2 Jack inputs (BLUE ACC1, SILVER ACC2).
    • Keyboard Input: A DIN port labeled KEYBOARD IN.
    • SCB Interface: Present (indicating Storz Communication Bus compatibility).
    • Power Input: Standard IEC input, along with a fuse holder underneath.

    Label Information

    The labels on the rear panel provide important technical information:

    • Power Rating and Fuse: Although input voltage or current value is not specified, “T1.6A 250V” is clearly indicated for fuse replacement.
    • Software Versions: Software version information such as “Dev SW: 670127-67A” and “SCB SW: …” is present on the label.
    • Safety Standards: Certified as “Medical Equipment” with a UL logo and “LR104841” CSA file number.
    • Serial No: “S/N: DF610343-P”.

    Camera Head (Endoscope Tip)

    The black-cabled unit resting on the housing is the camera head connected to the system.
    The connector structure features a multi-pin mechanism specific to Karl Storz units of that era. The lens part of the camera head is not clear in the visual, but the cable integrity appears to be preserved. The tape detail on the connector body should be carefully examined, as it might indicate an aesthetic defect or a repair sign.

    Documents and Manufacturing Year

    No invoice, user manual, or warranty certificate is found in the visuals. A clear manufacturing year (e.g., “MFG: 20XX”) is not visible on the label; however, considering the device’s design language and connector types (S-Video, Analog BNC), it is understood to be an older generation technology (likely early to mid-2000s).

    Potential Risk of Malfunction

    The product visually has a robust housing and shows no signs of drops or impacts. However, the following points should be within the user’s knowledge:

    • The device is an analog (PAL) system; it may not be directly compatible with modern Full HD or 4K digital systems, potentially requiring converters or a compatible analog monitor.
    • The tape on the camera head connector might indicate a weakness or looseness at the cable connection point, although no cable breakage can be detected from the visual.
    • The overall condition of the system appears good.