Secondhand Madsen AccuScreen Hearing Screening Device
Price: USD$ 320,00Approx: 13.440,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 24.07.2025
Madsen AccuScreen Hearing Screener Analysis Report
Overview and Product Description
The product shown in the images is the Madsen AccuScreen model, a medical screening device. The device is a handheld OAE (Otoacoustic Emission) and ABR (Auditory Brainstem Response) testing device used specifically for hearing screening in newborns. The product consists of the main device, two batteries, a charging adapter, and a carrying case. The visual analysis gives the impression that the product is original; the logo prints, button layout, and case quality reflect a professional manufacturing standard.
Brand and Model
The brand and model information of the device and its accessories in the images are specified below:
- Device Brand-Model: Madsen AccuScreen
- Case Brand: AccuScreen
Package Contents and Quantity Information
There are a total of 5 pieces of product and accessories in the images. The package contents are as follows:
- 1 Madsen AccuScreen main unit
- 1 carrying case with the AccuScreen logo
- 1 charging adapter and cable
- 2 external battery modules
Physical Condition and Deformation Analysis
The device is generally in a used condition. The most noticeable physical condition is a significant yellowing on the device’s white plastic case, which is thought to have occurred over time or due to environmental factors. Apart from this color change, there are no noticeable serious cracks, fractures, or dents on the case. The device’s screen is off, and no scratches or damage are visible on its surface. The surface of the keypad is clean, and the prints on it are legible.
Technical and Electronic Evaluation
The information obtained from the visuals about the electronic components of the device is limited, as the device is not shown in working condition. There are three connection ports on the bottom of the device:
- IR Window: A window for infrared data transfer.
- ABR Electrodes: An electrode connection socket for ABR testing.
- Ear Probe: An ear probe connection socket for OAE testing.
These port inputs appear to be in good physical condition and show no signs of bending or damage. It is understood that the device operates with two external batteries. The batteries do not have any visual issues such as swelling or leakage, but no comment can be made about their performance and remaining lifespan.
Accessories and Missing Parts
A carrying case, a charging adapter, and two batteries are provided with the device. The case appears clean and functional. However, it has been determined that the most critical accessories required for the device to perform its basic functions are missing. As understood from the port inputs, the Ear Probe and ABR Electrodes required to perform the tests are not present in the images. These shortcomings mean that the device cannot be used in its current state.
Potential Risks and Important Notes
Based on the visual inspection, the yellowing on the device’s case provides a clue about the product’s age or prolonged exposure to light. This condition could be a factor that may affect the performance of the electronic components and especially the batteries. Since the age and condition of the batteries are unknown, their charge-holding capacity may be low, or they may need to be replaced soon.
The most significant potential risk is the absence of the device’s basic testing accessories, the ear probe and ABR electrodes. Without these parts, hearing screening cannot be performed with the device. These notes are merely a forecast based on visual inspection and do not indicate a definitive malfunction.