Ready For Sale
Secondhand Medtronic Minimed 780G Insulin Pump
Price: USD$ 1.500,00 Approx: 67.500,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 06.02.2026
Medtronic MiniMed 780G Insulin Pump and Accessories Analysis Report
Device Identification
The examined visuals include an insulin pump, a medical device used for diabetes management, along with its user manual and spare part accessories in sealed packaging. The product is displayed as a set, within its original box.
Brand and Model
The inscriptions on the cover of the comprehensive user guide provided with the product and the accessory compatibility lists within the box contents have been examined. The brand and model information identified in light of the visual data is as follows:
- Brand: Medtronic
- Model: MiniMed 780G
The guide cover clearly states “MiniMed™ 780G” with “with the Guardian™ 4 Sensor” below it. Although the inscriptions “620G/630G/640G/670G” on the accessory packages indicate that the parts are also compatible with these models, the identity of the main device has been determined according to the model number on the guide cover.
Originality
The box design in the visuals, the barcoding system on the accessory packages, the font of the “Medtronic” logo, and the print quality of the user manual confirm that the product is an original Medtronic production. No inconsistencies raising suspicion of counterfeiting have been detected.
Areas of Use
The MiniMed 780G system is designed to manage insulin therapy in individuals with Type 1 diabetes. The device delivers basal and bolus insulin doses to the body in a programmed manner. “Guardian 4 Sensor” compatibility indicates that the system can monitor blood sugar levels by working integrated with Continuous Glucose Monitoring (CGM) technology. The spare battery cap and tubing clamps are necessary parts for the maintenance and safe use of this device.
Quantity Information
The contents of the set shown in the visuals are counted and listed as follows:
- 1 Insulin Pump Main Device
- 1 “System User Guide” Booklet
- 1 Original Product Box (Black)
- 1 Sealed Package Battery Cap Replacement Assembly
- 1 Sealed Package Tubing Clamps Kit (Contains 2 blue pieces)
- 1 Sealed Package Gasket/Cap Accessory
General Condition
The parts of the set should be evaluated in two different categories in terms of condition:
- Main Device (Insulin Pump): Is in used condition. There are clear signs of use on the device.
- Accessories: The battery cap and clip sets in the visual are in transparent, sealed bags and are unopened, thus they are in new/unused condition.
Physical Deformation
In the close-up analysis of the device presented in the third visual, intense scratches and friction marks have been observed on the screen and the black glossy frame around the screen. Especially in the middle and lower right part of the screen, superficial abrasions due to use are prominent. No cracks or fading are seen on the lower panel where the keypad is located.
Mechanical and Electronic Components
The navigation buttons (direction arrows), confirmation button, and back/menu buttons on the front of the device maintain their physical integrity; there is no sign of them being dislodged or sunken. The reservoir housing cover located at the top is in place. Since the screen is off (black), no comments can be made about pixel errors or electronic operating status based on the visual.
Accessories and Label Information
The technical codes on the packaged accessories within the box contents are as follows:
- Battery Cap Replacement Assembly: The reference code “ACC-1527” and production code “7006010-001_B” are legible on the label. A barcode containing the number “848337252” is also present. This part is explicitly stated as “Battery Cap Replacement Assembly”.
- Tubing Clamps Kit: The code “7005153-004_C” is located on the package. The product description is stated as “TUBING CLAMPS KIT 640G 21L”.
Potential Malfunction Risk
No signs of serious damage such as a deep crack, breakage, or corrosion/leakage in the battery compartment have been found on the device’s body in the visuals. The existing risk factor is the intensity of scratches on the screen; while this does not impair the device’s functionality, it may slightly reduce screen readability under intense light. Since the accessory packages are sealed, these parts are suitable for safe use.