Ready For Sale
Secondhand Medtronic Minimed 780G Insulin Pump
Price: USD$ 1.750,00 Approx: 78.750,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
If there is a local operation center in the seller's country:
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
If there is no operation center in the seller's country:
- Technical Inspection: Inspections are performed by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 02.02.2026
Medtronic MiniMed Series Insulin Pump Analysis Report
Device Identification and Brand/Model Information
The device shown in the visuals is an insulin pump, which is a medical equipment. Upon detailed examination of the product, the brand is clearly visible as Medtronic and the model family as MiniMed on the device’s rear label, stating “Medtronic MiniMed”. The technical codes “IC: 3408B-BLEPUMP” and “RF: M994838A002” on the rear label confirm that the device contains hardware with Bluetooth connectivity.
Originality Assessment
Upon examination of the product’s casing quality, label printing, interface software, and the regulatory marks on its rear (CE 0459, IPX8, Medtronic contact information and logo), the product has been assessed as an Original Medtronic device. The casing structure and keypad are in perfect alignment with the brand’s standard design language.
Areas of Use
This device is a medical apparatus used in diabetes management, providing patients with programmed basal insulin doses throughout the day and bolus insulin at meal times. It is designed for use by Type 1 diabetes patients. The device is portable and connects to the body via an infusion set.
General Condition and Cosmetic Examination
Upon visual inspection, the product was found to be in “used” condition. It is second-hand and shows signs of intensive use. The device retains its integrity, but cosmetic flaws are evident.
- Screen and Surface: In the fourth visual (with the screen off), intense hairline scratches and dullness are clearly visible on the screen or its protective layer. While these scratches are less noticeable in the first visual with the screen light on, surface wear is present.
- Keypad: The coating on the circular “confirm/select” button, located in the center of the directional keys on the device’s front face, is worn out, revealing the underlying material. This indicates the device has been used for an extended period.
- Casing Structure: No breaks or deep cracks are visible on the black hard plastic casing. The reservoir/battery cap slot located in the upper left part is in place.
Screen and Electronic Components Analysis
In visual 1, the device’s screen is seen to be operational. The blue backlit LCD screen is active. A main menu titled “Insuline” is displayed on the screen. The menu icons (Graph, Shield/Security, Sound/Speaker, Reservoir/Bottle, Drop, Checkmark, Connection, and Settings symbols) are clearly distinguishable. No dead pixels or stains could be identified from the visual; the text is readable.
Rear Label and Technical Data
Data read from the label on the back of the product is listed below. This information provides critical data regarding the device’s technical specifications and compatibility:
- Manufacturer: Medtronic MiniMed (Northridge, CA 91325 USA)
- Unit Indication: The phrase “mmol/L” is visible. This indicates that the device bases its blood sugar measurements and target values on millimoles per liter (especially important for the Turkish and European markets; may differ for users who use mg/dL).
- IP Class: “IPX8” (Indicates resistance to water up to a certain degree).
- Regulatory Codes: CE 0459 (Compliance with European Standards), MR (Symbol related to Magnetic Resonance safety), WEEE (Recycling bin symbol).
- Communication Frequency Codes: RF: M994838A002 and IC: 3408B-BLEPUMP (This code confirms that the device is from the “BLE” or Bluetooth Low Energy technology-equipped pump series).
Quantity and Accessory Information
The visuals show 1 unit of a Medtronic MiniMed insulin pump. No external accessories such as a clip, silicone case, infusion set, reservoir, box, or user manual are present in the visuals alongside the device. Only the main unit is seen.
Mechanical Components and Battery Status
The black cap (battery or reservoir slot cover) in the upper left corner of the device is present and closed. Since the device is shown in operational condition (screen on), it is understood to have an internal power source (battery), but the battery type or charge level cannot be determined from the visual. The physical forms of the buttons are preserved, but they exhibit paint wear.
Potential Malfunction Risk
The visuals do not show a warning screen indicating “System Error” or “Pump Error”; the menu screen appears stable. However, the intensive wear on the central button may indicate a reduced mechanical lifespan for this button. Scratches on the screen might affect viewing quality under very bright light or at certain angles. The possibility that the device’s IPX8 water resistance feature may have diminished over time due to micro-deformations in the casing or the condition of the cap seals (as they are not visible) is a general point of caution for second-hand waterproof devices. No physical damage that would completely impede the device’s function has been detected in the current visual state.