Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 05.08.2026
Report code: 1785914658

Medtronic Insulin Pump System and Accessories Analysis Report

Device and Product Identification

The images contain an insulin pump system used for diabetes management and various accessories belonging to this system. The main device is the insulin pump itself. Accessories include infusion sets, insulin reservoirs, electronic components thought to be sensors or transmitters, and adhesive tapes.

Brand Identification

The brand of the product has been identified as Medtronic. This information is verified by the logo seen on the adhesive tape packaging and on the screen of the main device. Model information is not clearly readable in the images.

Authenticity Assessment

The general appearance, packaging quality, logo details, and craftsmanship of the products in the images suggest that the products are authentic. No signs of counterfeiting have been observed.

Usage Areas

These products are used to manage blood sugar levels and provide continuous insulin for diabetic patients. The insulin pump ensures the regular and controlled delivery of insulin to the body. The accessories are the infusion sets, insulin reservoirs, and sensor components necessary for the proper functioning of this system. The products are suitable for use in the fields of endocrinology and diabetology.

Quantity Information

  • Insulin pump (main device): 1 unit
  • Green and gray circular device (sensor transmitter or charger): 1 unit
  • Small gray oval device (remote control or sensor component): 1 unit
  • Large gray oval device (charger or system component): 1 unit
  • Medtronic Oval Tape package (containing 10 units): 1 unit
  • Packaged infusion sets/reservoirs (white and blue): 34 units
  • Individually packaged syringes/reservoirs (with blue plunger): 20 units

There are a total of 58 products or product packages.

General Status and Condition

The general condition of the products is mixed. Many accessories (infusion sets, reservoirs, adhesive tapes) are in their original packaging and unused. The main insulin pump and other electronic components (green/gray and gray oval devices) appear to have been used but are in good physical condition.

Physical Deformations

There are slight scratches and fingerprints on the screen of the main insulin pump. There are no significant scratches, dents, or cracks on the casing in general. Slight wear or discoloration has been observed on the surface of the small gray oval device. No significant physical deformation has been detected in other products or packaging.

Mechanical Component Inspection

The buttons of the main insulin pump appear to be intact, and there are no signs of any mechanical issues. The casings and connection points of the other electronic components are also visually in good condition.

Electronic Component Analysis

The screen of the main insulin pump is active and displaying information. This indicates that the electronic components of the device are in working order. There is no externally visible malfunction or damage to the other electronic components.

Accessories and Connection Points

Essential accessories required for the system, such as infusion sets, reservoirs, and adhesive tapes, are present. The expiration date of the Medtronic Oval Tape package is stated as 2025-02-27. Socket inputs are visible on the main device, but closer images are needed for a detailed analysis of these parts. No external charging cable or adapter is visible in the images.

Battery Status

The battery indicator on the screen of the main insulin pump appears fully charged. This indicates that the internal battery is functional and holds a charge. No negative conditions such as swelling or leakage have been observed in the battery.

Label Information

  • REF Code: 7005739-014
  • Lot Number: 233106
  • Expiration Date (EXP): 2025-02-27

REF Code (Reference Code): A manufacturer-specific code that identifies a specific model or configuration of the product. This code ensures that the product is correctly identified and ordered.

Lot Number: A code indicating the batch or series in which the product was manufactured. This number ensures the traceability of the product and helps identify a specific production group in case of potential quality issues.

Expiration Date (EXP): Indicates the final date by which the product can be used safely and effectively. After this date, the performance or sterility of the product is not guaranteed.

The label also includes the “10x” marking, indicating that the package contains 10 units. The manufacturer information is listed as “Medtronic Minimed, Inc.” The CE mark indicates that the product complies with European Union health, safety, and environmental protection standards. Sterile and single-use symbols are also present.

Screen Analysis

The screen of the main device is on and functional. In the top left corner of the screen, there is a full battery icon and a question mark icon. The time “15:33” is displayed in the top right corner. The expression “— mg/dl” in the middle of the screen indicates that the blood sugar measurement value is currently not displayed or is empty. Below it, the text “0.0 U Act. Insulin” shows that the amount of active insulin is zero units. At the bottom of the screen, there is a “Reservoir + Set” warning inside a red band. This warning is a status message indicating that the insulin reservoir or infusion set needs to be checked or replaced. Navigation keys (up, down, left, right, center select key) and back/menu keys are visible below the screen.

Size and Compatibility

The products in the images are of compact size for personal use. The main insulin pump has a highly portable structure. The accessories, such as infusion sets and reservoirs, are of standard sizes compatible with Medtronic insulin pump systems. There is no specific measurement or size information in the images, but the general appearance of the products suggests they are suitable for standard adult use.

Production Year

The expiration date on the Medtronic Oval Tape label is stated as 2025-02-27. Since the shelf life of medical consumables is generally a few years, it can be estimated that these products were manufactured between 2020 and 2023. The design and screen interface of the main device have a modern appearance, suggesting that the device belongs to a relatively recent production period. There is no direct production year information in the images.

Documents

No invoices, warranty certificates, user manuals, or other documents belonging to the products are visible in the images. Therefore, no additional document information can be provided to the buyer.

Usage Duration

There is no information regarding the total usage hours or duration of use on the screen or labels of the device. This information could not be determined from the images.

Existing Malfunction

No clear evidence of malfunction, such as a broken part, severed cable, or a distinct error message (the “Reservoir + Set” on the screen is a status warning, not an error message), has been detected in the images. The device’s screen is operational, and it appears functional overall.

Potential Malfunction Risk

No concrete conditions that could pose a potential risk of malfunction, such as severe wear, rust, or cable crushing, have been observed on the main device or other electronic components. Although there is slight cosmetic wear on the used electronic components, the overall condition is considered to be good.