Standard

Secondhand Medtronic Minimed Paradigm MMT-715WWL Insulin Pump

SKU: MBFPR8QZ8MN

Ready For Sale

, , ,

Medbidding Engineers Verify

Secure Payment System

Price: USD$ 300,00 Approx: 15.000,00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 07.09.2026
Report code: 1788784013

Medtronic MiniMed Paradigm Insulin Pump Analysis Report

Device Identification and Basic Information

The product examined in the images is a portable insulin infusion pump used in diabetes management. The main unit of the device, a transparent protective carrying case, the original cardboard box, user manuals, and printed documents are included together.

  • Brand and Model: Medtronic MiniMed Paradigm 715
  • Product Type: Insulin Pump
  • Reference Code (REF): MMT-715WWL
  • Serial Number (SN): PCR488935H
  • Configuration Code (CONF): EFD6

Authenticity and General Condition

The product is authentic based on the official labels, serial numbers, CE conformity mark, and original brand logos present on it. The general condition of the device is clean, and it has been physically preserved within its protective case.

Usage Areas

This device is used to provide continuous and adjustable insulin infusion to ensure blood glucose control for insulin-dependent diabetic patients. It supports glycemic control by automating insulin therapy in the daily lives of patients under the supervision of endocrinology and internal medicine departments.

Quantity Information

  • 1 main insulin pump body
  • 1 transparent plastic carrying case and belt clip
  • 1 original cardboard storage box
  • Multiple booklets and user manuals

Physical Deformation and Mechanical Components

There are no breaks, cracks, deep scratches, or discoloration on the outer casing or the transparent protective case of the device. The keypad mechanism and the clip mechanism of the case are functional and in good condition.

Electronic Components

The keypad and control panel labels on the front surface of the device are clearly legible. The keys include the B key, the ESC key with an arrow icon, the ACT key written in white letters on a blue background, and function keys with warning and light icons.

Accessories

The images show the external protective transparent case, belt carrying clip, original product box, and numerous printed user manuals. No cables or external adapters are visible on the device. No sterile consumables with expiration dates were detected among the accessories.

Battery Status

According to the information stated on the rear label of the device, an -AAA(LR03)+ type battery is used as the power source. The battery compartment cover and the interior are visible in the image, and no negative conditions such as leakage or swelling were encountered.

Label and Text Inventory

The following inscriptions are legible on the technical label located on the rear panel of the device:

  • Medtronic MINIMED PARADIGM INSULIN PUMP
  • -AAA(LR03)+
  • 6025131-0U1 052505
  • Northridge, CA 91325 USA
  • 618-576-5555
  • Medtronic B.V. 6422 PJ Heerlen, NL
  • www.minimed.com
  • REF MMT-715WWL
  • CONF EFD6
  • SN PCR488935H
  • CE 0459/0976
  • IPX7
  • Rx Only

This label data verifies the device’s technical standards, serial number, production and compatibility codes, water resistance rating, and manufacturer contact locations. The IPX7 marking indicates that the device is protected against water for a certain duration. The Rx Only marking indicates that the product can only be obtained with a prescription.

Screen Analysis

The LCD screen on the front surface of the device is in the off state. No active menu, error code, or warning text is visible on the screen.

Dimensions and Compatibility

There is no direct millimetric measurement information in the images. However, it is observed that it follows the standard MiniMed Paradigm form factor, is designed in a portable size, and provides user compatibility thanks to the belt clip.

Year of Manufacture

There is no explicit year of manufacture written on the labels. Based on the examination of the device design, packaging graphics, and label typography, it is estimated to belong to the mid-2000s; the exact year of manufacture could not be determined from the image.

Documents

The images include numerous printed manuals, booklets, and spiral-bound user guides titled Paradigm At-A-Glance User Guide provided with the device. These documents enable the user to program and operate the device safely.

Usage Duration

Since the device screen is off and there is no counter on the labels indicating operating hours, there is no data regarding the usage duration.

Existing Faults

There is no evidence of faults such as breaks, detached parts, or error messages on the body of the device in the images.

Potential Fault Risk

No significant wear, corrosion, or cable damage has been observed on the outer casing of the device; its general condition is good.