Secondhand Medica EasyLyte Electrolyte Analyzer

, , , ,

Price: USD$ 500,00 Approx: 22.500,00 TL

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 13.05.2026
Report code: 1778677804

EasyLyte PLUS Na/K/Cl Analyzer Analysis Report

Device Identification

The device in the image is an electrolyte analyzer used in medical laboratories.

Brand and Model

The phrase EasyLyte PLUS Na/K/Cl ANALYZER is clearly legible on the front panel of the device. Based on this information, the brand of the device is EasyLyte, and the model is PLUS Na/K/Cl.

Usage Areas

This device is used to measure the levels of sodium (Na), potassium (K), and chloride (Cl) electrolytes in blood or other body fluids. It is suitable for use in hospital biochemistry laboratories, clinics, and emergency departments for diagnostic and treatment monitoring purposes.

Quantity Information

There is 1 EasyLyte PLUS Na/K/Cl analyzer device in the image.

General Condition

The device appears to have been used. There is contamination and staining on its outer casing and base plate. The screen is off, and it cannot be determined from the image whether it is in working condition.

Physical Deformation

Color fading and yellowing that have occurred over time are noticeable on the white plastic casing of the device. There are significant dirt deposits and stains, particularly on the base section and around the sampling area. No deep cracks or fractures are visible on the casing.

Mechanical Components

The “Yes” and “No” buttons on the front of the device are in place. The hoses and connectors that facilitate sampling and reagent flow appear to be attached. The section with the transparent cover on the right side and the peristaltic pump mechanism are in place. The condition of the hoses appears aged.

Electronic Components

There is an LCD screen on the front panel of the device. The screen is off. The back of the device or its internal electronic components are not visible in the image.

Accessories

The sampling and reagent hoses, pump mechanism, and electrode blocks are attached to the device. There are red and blue markers at the ends of the hoses. The power cable, reagent kits, calibrators, or other external accessories of the device are not present in the image.

Label Information

Other than the model name, no label containing specific technical information such as a serial number, lot number, or REF code is visible on the front panel of the device.

Screen Analysis

The LCD screen of the device is off. There is no text, error message, or menu display on the screen.

Size and Compatibility

There is no information in the image regarding the physical dimensions of the device or which patient group (adult/pediatric) it is suitable for. Such devices operate on samples in a laboratory environment.

Production Year

The production year of the device cannot be determined from the information in the image.

Documents

There are no documents such as an invoice, warranty certificate, or user manual belonging to the device in the image.

Usage Duration

There is no information on the screen or the casing regarding the total operating hours or duration of use of the device.

Existing Faults

No mechanically broken parts of the device are visible in the image. However, due to the screen being off and the general state of contamination, it cannot be determined whether the device is functionally operational or if it has any faults.

Potential Fault Risk

The contamination on the outer casing and the aged appearance of the hoses may indicate that the device has not been maintained for a long time. This situation may lead to issues with internal mechanisms, pumps, or the sensitivity of the electrodes. Hardening or clogging of the hoses may obstruct fluid flow. The condition of the device is moderate.