Sold Out

Whatsapp »
SKU: MBA8V3DGWTE

Secondhand Samsung PT10V Biochemistry Analyzer

Price: USD$ 2.175,00 Approx: 95.700,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 23.12.2025

    SAMSUNG Veterinary Blood Analyzer Review Report

    Device Identification and Brand Information

    The device shown in the image is a compact, desktop-form laboratory equipment used for medical diagnosis and analysis. At the center of the device’s front surface, the SAMSUNG brand is visible, written in white, clearly legible characters. On the gray label located at the bottom right corner of the device, the phrase “Veterinary blood analyzer” accompanied by a dog’s head silhouette is clearly seen. In light of this data, the device has been identified as a blood biochemistry analyzer used in animal health. Since there is no specific inscription regarding the device’s model (such as PT10V) on the front, the model name is not stated.

    Areas of Use

    The device, with its “Veterinary blood analyzer” inscription and dog icon, directly indicates that it is designed for use in veterinary clinics and animal hospitals. Its primary purpose is to assist in the diagnostic process by performing biochemical analysis of blood samples taken from animals. It is suitable for professional veterinary practices and laboratory environments.

    Physical Condition and Cosmetic Inspection

    Noticeable signs of use are observed on the device’s outer casing and screen surface. In terms of physical deformation:

    • Screen Surface: The device’s large black screen panel shows heavy fingerprints, smudges, and dust accumulation. Additionally, there is a high probability of fine scratches on the surface, but their depth cannot be fully discerned as the screen is off.
    • Casing Cleanliness: Dust and dirt accumulation are visible in the gaps of the upper bezel where the white plastic body meets the black screen. The device’s overall appearance falls short of a sterile environment standard and requires a detailed external cleaning.
    • Structural Integrity: No prominent deep cracks, breaks, or dents have been detected on the casing. The device retains its structural integrity.

    Hardware and Accessories

    In the setup shown in the image, there are at least two transparent liquid hoses extending from the left rear side of the device. These hoses are connected to two large plastic bottles (likely reagent, distilled water, or waste liquid reservoirs) standing on the right side of the device. There are no visible disconnections at the connection points. The accessory status is as follows:

    • Number of Devices: 1 Samsung analyzer.
    • Liquid Reservoirs: 2 clear/semi-clear canisters (as part of the liquid transfer system).
    • Hoses: Connection hoses for liquid transfer are present.

    Screen Analysis

    It is understood that the device has an integrated touchscreen. However, at the time of the image, the device is off or in standby mode, so the screen is completely black. No error codes, menus, or data are displayed on the screen.

    Overall Condition and Failure Risk Assessment

    The product is in “used” condition. It does not have the appearance of a new or refurbished product. There is no visual evidence of a mechanical or electronic fault (broken part, dangling cable, error warning on the screen). However, given the sensitivity required for laboratory equipment, the heavy dirt and dust accumulation on the device could pose a risk of performance degradation due to dust in the sensors or reader components. The fact that the device’s liquid hoses are connected suggests it was in recent use or is still part of an installed setup.