Ready For Sale
Secondhand Schiapparelli Biosystems Starlyte III Electrolyte Analyzer
Price: USD$ 500,00Yaklaşık: 21.500,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 18.08.2025
Schiapparelli Biosystems Starlyte III Analysis Report
Overview and Device Description
The product shown in the images is an electrolyte analyzer. The inscription “Na+ K+ Cl- Analyzer” on the device’s front panel indicates that it is used to measure sodium, potassium, and chloride ions. Such devices are typically used in medical laboratory settings to determine electrolyte levels in blood or other bodily fluids. One main device is present in the images.
Brand and Model Information
The brand and model information of the device is clearly legible on the labels on both the front and rear panels. Based on this information, the device’s identity has been definitively established.
- Brand: Schiapparelli Biosystems
- Model: Starlyte III
Physical Condition and Deformation Analysis
The general condition of the device is evaluated as used. Noteworthy points observed during the physical examination are listed below:
- General Condition: Yellowing and discoloration, which occurred over time, are observed on the device’s plastic casing, especially on the front and side surfaces.
- Surface Deformations: Various small scratches, stains, and light dirt accumulation resulting from general use are present on the casing. However, no major crack, break, or dent that would impede the device’s operation has been detected.
- Mechanical Components: The “YES” and “NO” buttons on the front panel are physically in place. The ventilation grilles and power input module on the rear of the device appear intact.
- Screen Condition: The main LCD screen and the smaller auxiliary display screen on the front panel are turned off. There are no significant scratches or cracks on the surface of the screens.
Technical Label Information
The manufacturer’s label on the device’s rear panel contains important technical details and identification information. This information includes:
- Model: STARLYTE III
- Serial Number: 05009456
- REF Code: RE6333
- Place of Manufacture: MADE IN THE USA
- Power Requirements: 90-250 VAC, 50-60 Hz, 1.4 Amps Max
- Other Codes: The label includes codes LR67076 and PIN 006184 REV B 5/99 next to the SP logo. The “5/99” notation suggests that the label or a part of the device might belong to a May 1999 revision.
Accessories and Equipment
No accessories (power cable, user manual, reagent kits, etc.) other than the device itself are visible in the images. Only the main body of the device is present. A standard power cable input and fuse slot are located on the rear of the device.
Conclusion and Evaluation
This report contains the analysis of the Schiapparelli Biosystems Starlyte III model electrolyte analyzer shown in the provided images. It has been determined that the device is used, with age-related discoloration and superficial scratches on its casing. However, no major physical damage has been observed generally. The device’s label information is legible, and important details such as the serial number and model have been clearly identified. Whether the device is functional or has any electronic faults cannot be determined from the images. The absence of visibly significant wear or damage indicates that the device’s physical condition is reasonable for its age.