Ready For Sale
Secondhand Hoyer Salvia Lifetec Alpha 101C Anesthetic Mechanical Ventilator
Price: USD$ 750,00Approx: 31.500,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 21.07.2025
Salvia Lifetec Alpha 1010 Ventilator Analysis Report
Overview and Product Description
The device shown in the images is a ventilator used for providing respiratory support. Based on the “SALVIA LIFETEC” and “ALPHA 1010” inscriptions on the front panel, the product has been identified as the Alpha 1010 model from the Salvia Lifetec brand. This medical device supports or completely takes over respiratory functions by delivering a controlled mixture of air and oxygen to patients.
In the analyzed images, there is a total of 1 ventilator main unit and 2 hoses belonging to the device.
Condition and Physical State
The overall condition of the device is assessed as used. Although the main unit’s casing has a generally clean appearance, slight color fading that may occur over time and minor signs of use are observed. The product is thought to be original and its workmanship to be in accordance with standards.
- Casing: No cracks, fractures, or serious dents have been detected on the plastic casing of the device. There may be superficial scratches on its surface resulting from general use.
- Front Panel: The inscriptions and indicators on the control panel are legible. The adjustment knobs, switches, and connection ports appear physically complete and undamaged.
- Hoses: There is significant wear on the white-colored hose among the accessories. Cracks, peeling, and flaking are visible at multiple points on the outer coating of the hose. It is understood that an attempt was made to repair these parts by wrapping them with tape. The physical condition of the black-colored hose is better compared to the white hose.
Mechanical and Electronic Components
Upon visual inspection of the device’s mechanical parts, no issues are apparent. All adjustment knobs (“Fluß l/min”, “Ventilatorbeatmung”, “Atemwiderstand”, etc.) and switches on the front panel are in place. The ventilation grilles on the back of the device are open and clean.
No comment can be made about the electronic components of the device as it is not in working condition. No screen or light indicator is active. There is a power input and a fuse holder on the rear panel.
Accessories and Connections
The following accessories have been identified with the device in the images:
- Hoses: There are two hoses in total, one white and one black. The physical condition of the white hose is quite poor.
- Power Cable: The power cable required for the device’s operation is not present in the images.
On the front panel of the device, there are connection ports for the “Ausatemventil” (Exhalation Valve) and “Vernebler” (Nebulizer). On the rear panel, there are two hose connection points and a standard power input. All connection points are visually undamaged.
Label and Technical Information
A label placed by the manufacturer on the device, containing detailed information such as the serial number and year of production, is not clearly legible. The label area on the rear panel, which likely contains this information, is either empty or the label has been removed. On the front panel, there is a label belonging to a technical service or distributor company named “Medikal Urządzenia SESAN”. A phone number is present on this label.
Current and Potential Fault Risks
The most distinct problem identified in the visual analysis is the severe wear on the white-colored hose. The cracks and flaking on the hose’s outer surface can pose a hygiene risk and may also cause air leaks, negatively affecting the device’s performance. Using this hose in its current state may not be safe, and it needs to be replaced.
There are no visible signs of damage or malfunction on the device’s main unit. However, using such medical devices, which appear to have been used or stored for a long time, without calibration and functional testing may pose potential risks. These stated potential risks are a forecast based solely on visual inspection and do not imply a definitive fault.