Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 03.01.2026
Breas Vivo 65 Mechanical Ventilator and Hardware Analysis Report
Device Identification
The main device examined in the visuals is an advanced mechanical ventilator system used to provide respiratory support. In addition to the main unit, an external humidifier unit is seen in the upper right corner of the visual, and equipment believed to be a carrying case is visible in the upper left part.
Brand and Model Information
As a result of a detailed visual examination, the brand and model information of the device has been identified as follows:
- Main Device Brand: BREAS
- Main Device Model: Vivo 65 (The inscription “Vivo 65 by Breas” is clearly legible on the front panel of the device.)
- Humidifier Model: SN-100 (The inscription “SN-100” is present on the front panel of the white device in the upper right part of the visual. Although the full brand is not visible, this code indicates standard respiratory device humidifiers.)
General Condition and Originality
The device is wrapped in a completely transparent protective packaging (stretch film or special protective gelatin) in the visual. This indicates that the device is either new (unused) or stored in a refurbished condition, having been packaged by the service after maintenance. The button layout, screen structure, and logo placement on the front face of the device perfectly match the original design language of the Breas Vivo 65 model. The workmanship and material quality appear to be top-tier from the visual and convey a sense of originality.
Physical Deformation and Protective Packaging
No cracks, fractures, or dents have been detected on the general casing of the device, in the visible areas (corners, keypads, frame). However, an important detail needs attention:
- Deformation on the Screen: In the area corresponding to the left-middle section of the screen, there is a distinct damage/stain resembling a tear or melting on the transparent protective packaging wrapping the device. While it cannot be definitively determined from the visual whether this damage is only on the packaging or has affected the underlying screen, the appearance strongly suggests that only the protective packaging is damaged. However, it is recommended to inspect the screen surface beneath the packaging.
Areas of Use
Breas Vivo 65 is a life support unit designed for patients requiring invasive (directly connected to the airway) or non-invasive (via mask) respiratory support in hospital or home care settings. It is suitable for use by pediatric (child) and adult patients. The accompanying humidifier unit is used to heat and humidify the airflow delivered to the patient, thereby increasing comfort and preventing airway dryness.
Electronic Components and Interface
The device in the visual is in the off position, therefore the screen is not active and pixel/image analysis cannot be performed. The control elements on the front panel are as follows:
- A large color LCD screen (Off).
- 5-way navigation buttons on the right side.
- 4 function buttons below the screen.
- A “Power/Start-Stop” button on the lower left.
- An “Alarm Mute” button on the lower right.
- Vertically positioned LED notification lights on the left side (symbols for mains electricity, battery status, alarm indication, etc., are present).
Accessories and Hardware
The hardware identified in the visual, apart from the main device, is as follows:
- External Heated Humidifier: A unit with model code SN-100, featuring temperature adjustment knobs, and visible with its water reservoir attached.
- Carrying Case: A grey, zippered bag, presumed to be compatible with the device, is partially visible in the upper left corner.
- Power Cable: A black power cable used for the power connection of the device or the humidifier is present.
Quantity Information
In total, the main set components seen in the visual are as follows:
- 1 Unit of Breas Vivo 65 Respiratory Device,
- 1 Unit of SN-100 Humidifier Unit (Partially visible),
- 1 Unit of Carrying Case (Partially visible),
- Various power cables
Battery Status
On the left side of the device’s front panel, there is an LED indicator with a battery symbol. The Vivo 65 model typically has an internal battery due to its technical specifications. However, since the device is off and the visual only shows its external appearance, no comments can be made about the battery’s current charge status or physical health (e.g., swelling). The casing integrity is maintained.
Potential Malfunction Risk
The device generally appears clean, protected, and in good condition. The only visible risk factor is the wear and tear on the packaging over the screen. If this wear was caused by a hard impact, the possibility of damage to that area of the screen should not be overlooked. Furthermore, since the condition of the humidifier unit’s water reservoir and its connection points are not clearly visible, it is recommended to check these parts for hygiene and leak-tightness. The overall appearance indicates that the device is in a well-maintained or near-new condition.