Sold Out

Whatsapp »
SKU: MB71G9QH3RX

Secondhand Home Mechanical Ventilator Hoffrichter Carat II

, , , ,

Medbidding engineers inspect before delivery.

Price: USD$ 1.800,00 Approx: 81.000,00 TL

Sold Out

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 05.06.2026
Report code: 1780650685

HOFFRICHTER CARAT II Ventilator Analysis Report

Device Identification and Brand Model Information

The image shows a medical device used to provide respiratory support. The brand names “CARAT II” and “HOFFRICHTER” are clearly legible on the front of the device. Based on this information, the device has been identified as a HOFFRICHTER CARAT II ventilator.

Authenticity Assessment

Upon examining the logo print on the device, the placement of the labels, and the overall build quality, the impression is that the product is original. No signs of counterfeiting or low-quality workmanship details have been observed.

Areas of Use

The HOFFRICHTER CARAT II is a ventilator designed for continuous or intermittent patient ventilation. It can be used to meet the respiratory support needs of both adult and pediatric patients. Although the device was specifically developed for home use, it is also suitable for use in clinical settings. It supports pressure-controlled or volume-controlled ventilation modes. It can be used for invasive (via tracheotomy) and non-invasive (via a respiratory mask) ventilation. It offers the possibility of ventilation with increased oxygen concentration by connecting to a low-pressure oxygen source. It can also be used in conjunction with humidifiers.

Quantity Information

There is one HOFFRICHTER CARAT II ventilator device in the image. There are no external accessories or additional parts visible with the device.

General Condition and Physical Deformation

The general condition of the device appears to be good and well-maintained. No physical deformations such as significant scratches, dents, cracks, or discoloration have been detected on the casing. No accumulation of dirt or dust has been observed on the surfaces.

Mechanical and Electronic Components

On the front panel of the device, there are two large respiratory hose connection points, one small connection point, and a switch. The control panel features mechanical components such as a large rotary knob, “menu”, “esc / mode” buttons, an on/off button, and an alarm button. There are no visible issues or damage to these mechanical parts. The screen, which represents the electronic component of the device, is active and provides a clear image.

Accessories and Socket Inputs

There are no cables or external accessories connected to the device in the image. On the left side of the device, there are two large circular socket inputs and one smaller socket input. These inputs are used for the connection of respiratory circuits. No wear or damage has been observed around the socket inputs.

Battery Status

There is no direct information or battery status indicator regarding the internal or external battery of the device in the image. The physical condition of the battery cannot be commented on from the image.

Label Information

There is no prominent label on the device in the image containing a serial number, lot number, REF code, or other technical information.

Screen Analysis

The device screen is on and active. Various numerical values and symbols are displayed on the screen. Values such as “20.0”, “5.8”, “12.0”, “3.0”, “0.3”, “0.50”, and “5.0” are listed in the upper left section. These values represent ventilation parameters or patient data. Expressions such as “1.10”, “AUS”, and “55” are located in the lower right part of the screen. The expression “AUS” may indicate that a function is turned off or disabled. On the right side of the screen, lung symbols and various warning icons (e.g., a bell with a cross) are visible. Abbreviations representing ventilation modes such as “Pcv”, “Psv”, “simv”, and “acv” are located at the bottom of the screen. The overall appearance of the screen is clear and legible; there are no pixel errors or image distortions.

Size and Compatibility

There is no numerical information regarding the exact dimensions or size of the device in the image. However, it is understood that the device has a portable structure from the integrated carrying handle located on the top. This suggests that the device is easily transportable in both home and clinical environments and is compatible with different areas of use.

Year of Manufacture

There is no direct information regarding the year of manufacture on the labels or the device itself in the image. The general design and screen interface of the device have a modern appearance. Its physical condition points to a new or very lightly used device. Based on these clues, it can be interpreted that the device was manufactured in the recent past.

Documents

No invoices, warranty certificates, user manuals, or other documents belonging to the device are visible in the image.

Usage Duration

There is no information regarding the operating hours or total usage duration on the device screen, labels, or any document visible in the image.

Existing Faults

No evidence of a clear fault such as a broken part, error message, disconnected cable, or missing component has been detected anywhere on the device in the image. The device appears to be in working order and without issues.

Potential Risk of Failure

The general condition of the device is quite good. No concrete details that could pose a potential risk of failure, such as severe wear, rust, or cable crushing, have been observed in the image. Based on its external appearance, the device is considered to be in good condition.