Secondhand Löwenstein Luisa LM150TD Home Mechanical Ventilator

SKU: MBRHO29KMG3

Ready For Sale

, , , , ,

Medbidding Engineers Verify

Secure Payment System

Price: USD$ 3.200,00 Approx: 150.400,00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 25.08.2026
Report code: 1787653049

Ventilator Analysis Report

Device Identification and Basic Features

The device in the image is a ventilation device used to provide respiratory support to patients. The main body of the product consists of a dark-colored casing, and a large touchscreen is located on the front surface. Transparent breathing circuits and hose connections are located at the bottom of the device.

Screen Analysis and Alerts

The device screen is on, and various operating values and warning messages are displayed on the interface. There is a warning strip with a red background at the top of the screen. Inside this strip, the warning Patient disconnection along with the instruction Check the hose system, the seating of the hose system connection, and the breathing inlet are displayed. This warning indicates an interruption or connection issue in the airflow path between the device and the patient. Instantaneous pressure and respiratory parameters are listed in the left column of the screen. Accordingly, the IPAP value is read as 2.6 hPa, PEEP value as 2.6 hPa, F value as 16.0 /min, Ti value as 1.70 s, I:E ratio as 1:1.2, VTe value as 0 ml, and MVe value as 0.0 /min. Therapy statistics are located in the middle section of the screen. Under the Therapy Patient heading, Usage time is displayed as 8287:39 h, Days used as 347 d, and Time/Day as 1433 min/day. Under the High Flow Therapy Patient heading, Usage time is stated as 0:00 h. These time values show the total operating history and usage intensity of the device to the recipient. In the right menu column, there are Ventilation, Alarms, Report, and System tab buttons.

General Condition and Physical State

The device is in a used condition. The screen surface is active, and the touch interface can be read without any issues. A green power indicator light is lit on the top right corner of the device casing. No physical deformations such as breaks, cracks, or dents are observed on the screen frame or the visible parts of the casing.

Mechanical and Electronic Components

There are transparent and flexible breathing hoses attached to the hose connection sockets located at the bottom of the device. The electronic components are in working order, and the screen backlight is active. Brightness and touch function icons are located in the bottom right corner of the screen.

Accessories and Battery Status

There are transparent breathing hose circuits connected to the device. The physical condition of the device’s internal or external battery cannot be fully seen from the outside, but there is a power plug icon and a green status light next to it in the top right corner of the screen; this indicates that the device is connected to an external power source.

Label and Text Inventory

The texts read on the screen interface in the image are; the 464 number indicating the error code, warning texts, therapy parameter abbreviations (IPAP, PEEP, F, Ti, I:E, VTe, MVe), and menu names. Physical labels or serial number tags are not visible within the frame of this image.

Dimensions, Compatibility, and Usage Time

There is no concrete measurement information regarding the physical dimensions or weight of the device in the image. The total usage time of the device is clearly recorded in the screen data as 8287:39 h; this data reveals how long the device has operated previously.

Manufacturing Year and Documents

Since the labels or documents of the device are not included in the image, the manufacturing year cannot be determined from the image. There are no invoices, warranty certificates, or printed documents in the images.

Current Fault and Potential Risk

There is an active warning message on the screen in the image. The Patient disconnection warning is an instantaneous status message informing that the hose system needs to be checked. No permanent physical fault risk such as a crack in the casing or a crushed cable has been observed in the image.

Quantity Information, Authenticity, and Usage Areas

There is 1 main ventilation device and breathing hose accessories connected to the device in the image. Since the brand and model logo of the device cannot be read from this angle, there is no visual evidence regarding its authenticity. The product is suitable for clinical and home care use in the treatment of patients experiencing respiratory failure or those in need of respiratory support.