Secondhand Puritan Bennett 560 Home Mechanical Ventilator

SKU: MB2V23ZF48X

Ready For Sale

, , , ,

Medbidding Engineers Verify

Secure Payment System

Price: USD$ 2.660,00 Approx: 125.020,00 TL
Bid

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 14.07.2026
Report code: 1784014777

COVIDIEN Puritan Bennett 560 Ventilator Analysis Report

Device Identification and Credentials

The images show a ventilator device, a carrying case, and a power cable. As clearly visible on the device screen, the product brand is identified as COVIDIEN Puritan Bennett and the model as 560 Ventilator. The logo quality, screen clarity, and general workmanship details indicate that the product is authentic.

Usage Areas of the Product

The ventilator is a medical device used to provide mechanical respiratory support to patients experiencing respiratory failure. This device assists patients in breathing by increasing air movement into their lungs. It is suitable for use in various healthcare settings such as intensive care units, emergency departments, and home care environments. It is of vital importance, especially for patients who cannot breathe on their own or have difficulty breathing.

Physical Condition and State

The general condition of the device appears good and clean. There are no visible scratches, dents, or cracks on the casing. No color fading or heavy dirt has been observed. All components, including the carrying case and power cable, are in good condition.

There are a total of three items and accessories in the images: one ventilator device, one carrying case, and one power cable.

Mechanical and Electronic Component Inspection

The casing and plastic parts of the device are clean. The buttons on the control panel and other elements appear to be intact. The screen itself is physically undamaged and provides a clear image. No visible issues have been detected in the mechanical parts.

Accessories

  • Carrying Case: A gray, zippered carrying case is included with the device. The case features a transparent window and a carrying strap. The zippers and overall structure appear to be sturdy.
  • Power Cable: One black power cable is present. There is a cylindrical ferrite bead on the cable. The cable ends consist of a European-type two-pin plug and a figure-eight connector for device connection. No breaks or crushing have been detected on the cable.

No socket input is clearly visible on the device in the images. There is no information in the images regarding the status of the internal or external battery.

Screen Analysis and Data

Various respiratory parameters are displayed on the device screen under the heading “VENTILATION REPORT”. The report date is stated as “05 JUN 2026”. The displayed parameters and their meanings are as follows:

  • Averajvent: Shown as 23 h 9 min.
  • VTI (Inspiratory Tidal Volume): The amount of air delivered to the patient’s lungs, stated as 51 mL.
  • VTE (Expiratory Tidal Volume): The amount of air exhaled from the patient’s lungs, shown as 0 mL.
  • PIP (Peak Inspiratory Pressure): The peak inspiratory pressure, measured as 9 mbar.
  • F (Respiratory Frequency): The respiratory rate, stated as 9 b/min.
  • Leak: Refers to the air leak occurring during mechanical ventilation, shown as 0 Ew s.
  • Apnea: Refers to the duration of respiratory arrest, stated as 0 s.
  • Apnea T: Refers to the apnea time, stated as 0 s.
  • Spont (Spontaneous Breathing Percentage): The percentage of the patient’s spontaneous breathing contribution, stated as 57 %.

At the bottom of the screen, “Machine : 01771 h” and “Patient : 01021 h 32 min” information is provided. Below the screen, there is a “Back” text and various functional icons.

Dimensions and Portability

Specific dimension information for the product is not included in the images. However, the fact that the device is presented with a carrying case suggests that the Puritan Bennett 560 model has a lightweight and compact structure, making it easily portable from a hospital environment to home use or different healthcare settings.

Production Period and Documents

There is no concrete information regarding the production year on the product labels or in the images. No documents such as invoices, warranty certificates, or user manuals were encountered in the images.

Usage Duration and Potential Risks

The total usage durations, “Machine : 01771 h” and “Patient : 01021 h 32 min”, are clearly stated on the device screen. These data indicate the total operating time of the device and the duration of use connected to a patient.

The general condition of the device in the images is good, and no situations that could pose a potential risk of failure, such as severe wear, rust, or cable crushing, have been observed. The current state of the device suggests it is in good condition. No clear evidence of failure, such as error messages, broken parts, or missing components, has been detected in the images.