Disclaimer: I am Medbidding AI. I am an unbiased AI agent. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 15.09.2026
Report code: 1789453967
COVIDIEN Puritan Bennett 560 Ventilator Device Analysis Report
Device Identification and Basic Information
The device shown in the images is a respiratory support device. The product brand is identified as COVIDIEN, and the model as Puritan Bennett 560. The ventilation report and operating values are displayed on the screen on the front of the device.
Brand and Model
The inscription COVIDIEN Puritan Bennett 560 Ventilator is clearly legible on the top panel of the device. The model code has been transferred to the report by adhering to the original spelling, without omitting any letters or numbers.
Authenticity and General Condition
The front panel workmanship, screen placement, and logo quality comply with original product standards. The device is used but is in clean general condition.
Usage Areas and Compatibility
This device is used in clinical settings or home care processes to ventilate the respiration of patients experiencing respiratory failure or those in need of respiratory support.
Quantity Information
The images include one ventilator main unit, one gray carrying case, and one power cable.
Physical Deformation and Mechanical Components
There are no cracks, deep scratches, or color fading on the front plastic casing or around the screen of the device. The keypad and mechanical connection slots are in sound condition.
Electronic Components and Screen Analysis
The electronic screen of the device is operational, displaying white text and data on a blue background. The values read on the screen signify the following:
- Averajvent: 23 h 9 min (Indicates the average ventilation time.)
- 05 JUN 2026 (Indicates the date the report was generated or the system date.)
- VTI: 51 mL (Indicates the inspiratory tidal volume value.)
- VTE: 0 mL (Indicates the expiratory tidal volume value.)
- PIP: 9 mbar (Indicates the peak inspiratory pressure value.)
- F: 9 b/min (Indicates the respiratory frequency.)
- Leak: – (Indicates that there is no leak in the circuit or it is not measured.)
- Apnea: 0 Ev s (Indicates the number of apnea events.)
- Apnea T: 0 s (Indicates the duration of apnea.)
- Spont: 57 % (Indicates the spontaneous breathing rate.)
- Machine: 01771 h (Indicates the total operating hours of the device.)
- Patient: 01021 h 32 min (Indicates the usage time connected to the patient.)
Accessories
The images include a zippered carrying case made of gray textile material for the device and a black power adapter cable with a standard plug end. No deformation or crushing was observed on the cable.
Battery Status
There is no external battery slot or additional indication regarding battery status in the images; the internal battery status could not be determined from the visuals.
Label and Text Inventory
The front panel of the device contains the inscriptions COVIDIEN, Puritan Bennett 560 Ventilator, VENTILATION REPORT, menu labels, and parameter abbreviations (VTI, VTE, PIP, F, Leak, Apnea, Spont, Machine, Patient). The power cable features a standard plug form and connection socket.
Dimensions and Compatibility
There is no numerical measurement information regarding the physical dimensions or weight of the device in the images.
Year of Manufacture
The date 05 JUN 2026 appears on the screen; however, this is the system report date, and the actual year of manufacture of the device is information not present in the images.
Documents
There are no invoices, printed warranty certificates, or user manuals in the images.
Usage Duration
According to the data read from the device screen, the machine operating time is recorded as 01771 h (1771 hours), and the patient usage time is recorded as 01021 h 32 min.
Existing Faults and Potential Risk of Failure
No error messages, broken parts, or signs of failure were found in the screen data and outer casing examined in the images. No serious wear was observed on the cable structure or the casing; the general condition of the device is good.