Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 22.07.2026
Report code: 1784720920
COVIDIEN Puritan Bennett 560 Ventilator Analysis Report
Device Identification and Brand Model Information
The images feature a ventilator and its associated accessories. Based on the logo and text on the front of the device, it has been clearly identified as a COVIDIEN Puritan Bennett 560 Ventilator.
Authenticity Assessment
Upon examining the COVIDIEN and Puritan Bennett logos on the device, the screen quality, and the general craftsmanship details, the impression is that the product is authentic.
Usage Areas
This device is a ventilator used to support or completely take over the respiratory functions of patients. It is suitable for providing mechanical ventilation to patients experiencing respiratory failure in intensive care units, emergency departments, operating rooms, and home care environments. The device provides life support by monitoring and adjusting the patient’s respiratory parameters.
Quantity Information
- 1 unit of COVIDIEN Puritan Bennett 560 Ventilator
- 1 gray carrying case
- 1 black power cable
General Condition and Physical Deformation
The general condition of the ventilator appears to be good. No significant scratches, dents, cracks, or discoloration have been detected on the device’s casing, screen, or other visible surfaces. The carrying case and power cable are also clean and in undamaged condition.
Mechanical and Electronic Component Inspection
There are no visible issues with the mechanical components of the device, namely its casing and buttons. The screen is actively working and clearly displaying data. This suggests that the electronic components are functional.
Condition of Accessories
The device comes with one gray carrying case and one black power cable. The zippers on the carrying case appear to be sturdy, and it features a transparent label window. The power cable has a two-prong European-type plug and a device connection end; there is a ferrite bead on the cable. There are no missing parts or expiration date information visible in the images regarding the accessories. Socket inputs are not visible on the device, but the connection point for the power cable is present.
Battery Status
The images do not provide information regarding the physical condition (swelling, leakage, etc.) of the device’s internal or external battery. However, the fact that it is a portable ventilator suggests that it has an internal battery.
Label Information and Technical Details
Label information such as serial number, lot number, or REF code is not clearly readable on the device in the images. However, some technical information and usage data are available on the screen:
- VTI (Volume Tidal Inspiratory): 51 mL. This value indicates the volume of air delivered to the patient with each breath.
- VTE (Volume Tidal Expiratory): 0 mL. This value indicates the volume of air exhaled by the patient. This value in the image may have been reset at the beginning of the measurement or at a specific moment.
- PIP (Peak Inspiratory Pressure): 9 mbar. This refers to the highest pressure applied to the lungs during inhalation.
- F (Frequency): 9 b/min. This shows the number of breaths per minute.
- Leak: 0 Ew s. This indicates the amount of air leakage in the system. Being zero indicates good sealing.
- Apnea: 0 s. This is the duration of the patient’s respiratory pause.
- Apnea T: 0 s. This may refer to the apnea duration threshold or total apnea duration.
- Spont (Spontaneous Breathing Percentage): 57 %. This shows what percentage of the patient’s total respiratory effort is spontaneous.
Screen Analysis
The device’s screen is on and functional. At the top of the screen, there is a “VENTILATION REPORT” header and a report date and time displayed as “23 h 9 min on 05 JUN 2026”. In the main section of the screen, ventilation parameters such as VTI, VTE, PIP, F, Leak, Apnea, Apnea T, and Spont, along with their numerical values, are listed. At the bottom of the screen, there are usage durations displayed as “Machine : 01771 h” and “Patient : 01021h32min”, as well as a “Back” navigation option. All text and values on the screen are clearly readable.
Size and Compatibility
The fact that the device is presented with a carrying case indicates that the product has a portable structure and can be easily moved at home or in different healthcare settings. This suggests that the device is designed to support patient mobility.
Manufacturing Year
There is no direct label or document regarding the manufacturing year of the device in the images. However, the date “05 JUN 2026” visible on the screen indicates that the device generated a report or was in use on this date. This information reveals that the device was actively used at least until 2026.
Documents
No additional documents such as invoices, warranty certificates, or user manuals belonging to the device are visible in the images.
Usage Duration
The usage durations are clearly stated on the device’s screen:
- Machine usage duration: 01771 hours
- Patient usage duration: 01021 hours 32 minutes
These data show the total operating time of the device and how long it has been used for a specific patient.
Existing Fault
No clear evidence of a fault such as a broken part, error message, severed cable, or missing component has been detected in the images. The fact that the screen works properly and displays parameters suggests that the device is performing its basic functions.
Potential Fault Risk
No concrete signs that could pose a potential fault risk, such as severe wear, rust, or crushing, have been observed on the device’s casing, accessories, or cables in the images. The general condition of the device is good.