Ready For Sale

Whatsapp »
SKU: MBM6EWVV53Q

Secondhand Weinmann Ventilogic LS Home Mechanical Ventilator

Price: USD$ 3.000,00 Approx: 132.000,00 TL

, , , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Free Shipping Conditions

      You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.

      Conditions

      • The product must be sold for $400 USD or more.
      • Both the buyer and the seller must be located in Turkiye.

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 11.11.2025

      Weinmann Ventilogic LS Ventilator Analysis Report

      Overview and Device Identification

      The visuals show a mechanical ventilator (respiratory device) used to provide invasive and non-invasive respiratory support, and a black carrying case belonging to this device. The purpose of the device is to provide controlled air or oxygen support to patients experiencing respiratory failure. A total of 2 items are visualized: 1 ventilator device and 1 carrying case.

      Brand and Model Information

      Through detailed visual analysis and the clear writing on the screen, the brand and model of the device have been clearly identified. The device is the Ventilogic LS model from the Weinmann (Löwenstein Medical) brand. This information is legibly displayed on the device’s screen when it is powered on and operational. It is understood from the professional structure, screen quality, and details on its casing that the product is an original device.

      Physical Condition and Deformation Analysis

      The general condition of the device is quite good, and it appears to have been used. No significant deformations such as scratches, dents, cracks, or discoloration are observed on its white main casing. The surface is generally clean. There is a label titled “Berdan Medikal” on the top part of the device. This label has slight lifting at its edges and handwritten notes that are difficult to read. Mechanical components such as the rotary control knob, power button, and other function keys appear visually sound and functional.

      Screen and Operational Status Analysis

      The device’s screen is operational, and the image quality is clear. The green light on the power button indicates that the device is active. There are no pixel errors, scratches, or darkening on the screen. The technical data and status information visible on the screen at the time of analysis are as follows:

      • Model Name: VENTIlogic LS
      • Active Mode: PSV (Pressure Support Ventilation)
      • Program: 1
      • Status Message: Single limb valve.
      • IPAP Value: 18.0 hPa
      • PEEP Value: 6.0 hPa
      • Respiratory Rate (f): 13.5 /min.
      • Inspiration Time (Ti/T): 30 %
      • Tidal Volume (VTi): 3000 ml

      Additionally, an SD card icon and a muted alarm icon are visible on the screen. This data indicates that the electronic components of the device are functioning and that it is set up for respiratory therapy.

      Accessories and Complementary Equipment

      In addition to the device, the visuals also show a black, original carrying case. A power cable connected to the device is visible, but other accessories such as the patient breathing circuit (hose and mask) are not present in the visuals. On the front panel of the device, there is an air outlet port where the breathing hose is attached, bearing the inscription “Ø 15mm – 22mm”. This indicates that the device is compatible with standard diameter breathing hoses.

      Labels and Technical Details

      An original manufacturer’s serial number or production date label is not clearly visible on the device. The service label on the top part contains the “Berdan Medikal” logo and contact information. Fields such as “Device Serial No” on this label were observed to be blank or illegible. This label indicates a technical service or supplier company, not the device manufacturer.

      General Assessment and Potential Risk Analysis

      Based on the examination of the visuals, it has been concluded that the device is in good technical and physical condition. The seamless operation of its electronic screen and the absence of any error messages indicate that the device is functional. No significant defects such as serious wear, rust, or crushed cables that could pose a potential risk of malfunction were detected on its casing. Cosmetically, only the slight wear observed on the upper service label is not a condition that would affect the device’s operation. The device’s overall condition suggests it has been used carefully.