Ready For Sale

Whatsapp »
SKU: MBSJ6XZCCKC

Secondhand Weinmann Ventilogic LS Home Mechanical Ventilator

Price: USD$ 1.850,00 Approx: 81.400,00 TL

, , , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Free Shipping Conditions

      You can benefit from our FREE SHIPPING campaign for your purchases in this category. Medbidding covers all shipping costs for both the buyer and the seller on orders that meet the conditions below. For all international sales and domestic sales within Turkiye that do not meet these conditions, Medbidding’s standard shipping procedures will apply.

      Conditions

      • The product must be sold for $400 USD or more.
      • Both the buyer and the seller must be located in Turkiye.

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 10.11.2025

      Löwenstein Medical VENTIlogic LS Ventilator Analysis Report

      Overview and Device Description

      The visuals show a medical ventilator device used to provide respiratory support. The device is designed for both invasive and non-invasive ventilation in areas such as intensive care units, hospitals, and home care. The set consists of a main unit, its carrying bag, and various consumables and accessories. In total, there is one ventilator device, one carrying bag, and more than ten individually packaged accessories.

      Brand and Model Information

      From the logos and inscriptions on the front and rear panels of the device, the product’s brand has been clearly identified as Löwenstein Medical. The device’s model, also clearly written on its front and rear labels, is VENTIlogic LS. This information is clearly legible in the visuals and presents no ambiguity.

      Physical Condition and Deformation Analysis

      The general condition of the device is assessed as used. Noteworthy details from the physical examination are as follows:

      • Main Unit: No major cracks, breaks, or dents were observed on the white plastic casing of the device. There are light dirt and stains on its surface due to general use. Overall, its casing is robust.
      • Screen: The device’s screen is off. There are numerous fine scratches, smudges, and wipe marks on the screen surface. The depth or permanence of these marks cannot be determined from the visuals, but they suggest the screen has been used or cleaned extensively.
      • Carrying Bag: The surface of the black carrying bag shows noticeable white scuff marks, stains, and dust. The condition of the bag indicates heavy use.

      Technical Details and Label Information

      The following technical information was obtained from the manufacturer’s label located on the back of the device:

      • Type (TYP): VENTIlogic LS
      • Serial Number (SN): 47575
      • Electrical Requirement: 100-230 V, 50-60 Hz, 0.8-0.35 A
      • Date of Manufacture: 2020-08 (August 2020)
      • Protection Class: IP21
      • Place of Manufacture: Made in Germany
      • Certification: CE 0197
      • Manufacturer: Löwenstein Medical Technology GmbH + Co. KG, Hamburg, Germany

      The label also includes an inspection sticker indicating a technical check or calibration that should have been performed by the 11th month of 2022 at the latest. The fact that this date has passed suggests that the device may require maintenance. A warning symbol indicating suitability for tube diameters of 15mm – 22mm is present at the patient circuit outlet.

      Accessories and Equipment

      The accessories included with the device are as follows:

      • Carrying Bag: A black bag, without the Löwenstein Medical inscription, used for transporting the device and its accessories.
      • Filters: One white, accordion-style particle filter in its original packaging and two black, sponge-type coarse dust filters are visible.
      • Plastic Connectors and Parts: Numerous white and red plastic connection pieces, adapters, and caps of various sizes and types, each individually packaged in clear bags, are present.

      On the rear panel of the device, there is a power input socket protected by a metal latch and a circular connector that can be used to establish a connection with another device.

      Potential Condition Assessment

      The device’s casing is generally in good condition and shows no signs of significant physical damage. The fact that most of the accessories are new and packaged is a positive aspect. However, the extensive scratches on the device’s screen and the wear and tear on the carrying bag indicate that the product has been used. The functionality of the device cannot be tested via the visuals. The expired 2022 maintenance sticker on the rear label suggests that it is recommended for the device to be checked and calibrated by a professional technical service to ensure its safe and proper operation.