Ready For Sale

Whatsapp »
SKU: MBL28S62OWI

Secondhand Draeger Devita XL Intensive Care Mechanical Ventilator

, ,

Price: USD$ 6.100,00 Approx: 274.500,00 TL

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      If there is a local operation center in the seller's country:

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      If there is no operation center in the seller's country:

      • Technical Inspection: Inspections are performed by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 02.03.2026

      Dräger EvitaXL Intensive Care Ventilator Analysis Report

      Device Identification

      The device in the visuals is an advanced mechanical ventilator unit standing on its integrated trolley. The device is a stationary type of medical equipment designed for intensive care unit use.

      Brand and Model

      The “Dräger” brand logo is clearly and legibly located on the front upper left corner of the product, and the “EvitaXL” model designation is on the upper right corner. The device’s characteristic design, control panel, and screen structure confirm this identification. Brand and model identification is 100% certain.

      • Brand: Dräger
      • Model: EvitaXL

      Originality

      The casing structure, the membrane keypad on the control panel, the design of the rotary knob, and the corporate logo placement are entirely consistent with Dräger’s production standards. The device has been evaluated as an original OEM product.

      Areas of Use

      It is used to provide invasive and non-invasive mechanical ventilation support for adult, pediatric, and neonatal (neochat – optional) patient groups. It is suitable for use in post-anesthesia recovery rooms and all levels of intensive care (Resuscitation, Cardiovascular Surgery, Internal Medicine).

      Quantity Information

      • 1 Unit Dräger EvitaXL Ventilator Main Unit
      • 1 Unit Original Dräger Transport Trolley

      General Condition

      The device is in used (second-hand) condition. It appears to have been stored in a warehouse or workshop environment. There are clear signs of use and shelf/storage dust on the device. It is located in a service or waiting area rather than a sterile environment.

      Physical Deformation

      • Casing: The device casing and screen frame are generally dirty and dusty. Superficial dirt is present on metal and plastic parts. No major crack or dent compromising the casing integrity has been identified in the visual.
      • Color: Slight yellowing and dirt accumulation due to age are observed on the plastic parts (especially the upper and side sections of the screen).
      • Stand/Trolley: While no serious rusting is visible on the trolley frame, there are signs of friction on the paint and a layer of dirt on the wheels.

      Mechanical Components

      The membrane keypad on the control panel is physically in place. The main rotary selection knob on the lower right corner of the screen is present. The blue locking mechanisms at the bottom of the device are in place. The height adjustment column and wheels on the trolley appear physically sound, but their mobility has not been tested.

      Electronic Components

      The device is in the off state in the visual. There is no visual data regarding the functionality of the electronic components. The screen panel appears intact.

      Screen Analysis

      The device has a large TFT LCD screen known to have touch capabilities. The screen is currently off (black). No deep scratches or cracks are visible on the screen surface, but the surface is dusty. Any dead pixels or backlight issues could not be analyzed as it is off.

      Accessories and Missing Items

      The equipment status on the device is as follows:

      • Available Accessories: Mobile transport trolley is present. The yellow/orange protective corner bumpers on the front wheel legs of the trolley are in place.
      • Missing Accessories: Patient breathing circuit (hoses) is not attached. Humidifier unit is missing. Patient circuit support arm is not present on the trolley. Although the expiration valve and flow sensor group cannot be clearly distinguished from the visual, the front panel connections appear empty. Electrical and gas connection hoses are not visible in the visual.

      Battery Status

      The device has an internal battery, but it is not externally visible. Since the screen is off, no visual comment can be made regarding the battery’s charge level, health, or presence (whether it is inside).

      Label Information

      Apart from the brand and model label on the front, the “Ref/SN” label containing the technical serial number or production year is not visible from this perspective (it is usually located on the rear panel). The front panel button function icons are clear and legible.

      Dimensions and Compatibility

      It is sized appropriately for standard intensive care bedside use. The transport trolley is sized to allow for the device’s mobilization within the hospital.

      Current Fault

      There is no active “Hata/Error” message in the visual because the device is off. However, no concrete fault indication, such as a mechanical break or fragmentation in the outer casing, has been visually identified.

      Potential Fault Risk

      The heavy dust accumulation on the device’s exterior surface indicates that dust may also have accumulated on the internal fan and electronic boards; this could increase the risk of overheating. Furthermore, open pneumatic inlets raise the possibility of dust entering the system. Consumables such as the oxygen sensor and battery are likely to have reached the end of their lifespan.