Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 21.04.2026
Report code: 1776781303
Medical Chair Analysis Report
Device Identification
The images show a medical chair with a motorized mechanism and adjustable sections. The device consists of a backrest, a seat, a footrest section, and armrests.
Brand and Model
A detailed examination of the images revealed no logos, text, labels, or technical information plates indicating the brand or model of the device. Therefore, brand and model information is not included in the report.
Authenticity
The upholstery quality, stitching craftsmanship, and the structure of the metal components present the appearance of a standard medical product. No definitive conclusion regarding authenticity can be drawn from the images.
Usage Areas
Such motorized medical chairs are used to keep patients in a comfortable and appropriate position during examinations, treatments, or specific procedures. Thanks to its adjustable structure, it is suitable for use in dermatology, podiatry, aesthetic applications, or general examination rooms.
Quantity Information
The images show 1 medical chair and 1 associated wired foot pedal.
General Condition
The general condition of the device is evaluated as used. While no significant tears or rips are visible on the upholstery, there are signs of wear on the metal and plastic components.
Physical Deformation
No color fading or large stains were observed on the chair upholstery. However, there are scratches and surface abrasions on the hard black plastic or metal part at the very end of the footrest section. Slight dirt and usage-related wear are visible on the metal connection points and mechanism parts of the armrests.
Mechanical Components
The backrest, footrest, and armrest mechanisms are visually in place. The screw mechanisms that provide height adjustment for the armrests and the hinge structure at the foot end appear to be intact. The functional status of the moving parts cannot be determined from the images.
Electronic Components
A foot pedal controlling the motorized structure of the device and its associated cables are visible. There is a label on the foot pedal marked “MASA YUKARI” (TABLE UP). No serious damage, such as breaks or crushing, has been visually detected in the outer insulation of the cables. Whether the electronic system is operational cannot be determined from the images.
Accessories
An integrated head pillow and 1 wired foot pedal are present. No other accessories or spare parts are visible. There is a standard electrical plug at the end of the foot pedal cable.
Battery Status
There is no visual evidence that the device has an internal or external battery. It is understood that the device operates directly via mains electricity.
Label Information
No technical label or plate containing a serial number, lot number, REF code, or production year was detected on the device. There is only a simple label on the foot pedal indicating its function.
Screen Analysis
There is no digital screen or display panel on the device.
Dimensions and Compatibility
There is no visual information regarding the dimensions or patient weight capacity of the device. Given its structure, it appears suitable for use by adult patients.
Production Year
No label or document regarding the production year of the device is present in the images.
Documents
No documents such as invoices, warranty certificates, or user manuals are visible in the images.
Usage Duration
There is no information available regarding the total usage hours or duration of the device.
Existing Faults
There is no clear evidence in the images, such as broken parts or error messages, indicating that the device is mechanically or electronically faulty.
Potential Risk of Failure
Apart from surface abrasions on the footrest section and dirt on the mechanical connection points, no serious wear has been observed. The condition of the cables appears good. These abrasions do not pose a critical risk that would directly affect the function of the device. The general condition of the device is at an acceptable level for a used product.