Secondhand Sesan MT-016 10 Liters Steel Oxygen Cylinder with Valve

, , ,

Price: USD$ 60,00 Approx: 2.700,00 TL

Sold Out

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 12.11.2025

Oxygen Cylinder and Regulator Analysis Report

Overview and Product Description

The visuals show an oxygen cylinder, understood to be for medical purposes, along with a pressure regulator, flowmeter, and humidifier chamber mounted on it. This set is a standard mobile oxygen delivery system used to administer oxygen therapy to patients. The primary function of the product is to reduce the high-pressure oxygen within the cylinder to a safe pressure and flow rate suitable for the patient to breathe, delivering it in a humidified form.

Quantity Information

The products and accessories shown in the visuals are listed below:

  • 1 blue Oxygen Cylinder
  • 1 Pressure Regulator and Manometer (Pressure Gauge)
  • 1 Flowmeter
  • 1 Humidifier Chamber

General Condition and State

The general condition of the product set is assessed as used. No significant rust or corrosion is observed on the metal components of the device. Plastic components appear intact and maintain their integrity. The needle of the pressure gauge on the manometer is at the zero (0) position, indicating that the cylinder is empty or the system is closed. The device generally gives the impression of being in working condition, but there are slight signs of wear due to use.

Physical Deformation and Cosmetic Condition

Upon examining the physical condition of the product, no serious deformation has been detected. The blue oxygen cylinder’s body has a white protective mesh, and no significant scratches, dents, or peeling paint are observed on the cylinder. The chrome-plated metal surface of the regulator has slight stains and signs of use. The brass connection elements at the top are in normal condition. The humidifier chamber has a transparent and clean appearance, with no cracks or breaks.

Mechanical and Technical Component Analysis

All mechanical parts are visually in good condition. No breakage or obvious damage has been detected on the main valve on the oxygen cylinder, the green flow adjustment valve (SHUT/OPEN) on the regulator, or other connection points. The glass of the manometer (pressure gauge) integrated into the regulator is intact, and its internal scale is clearly readable.

Manometer (Pressure Gauge): The analog gauge features colored zones (green, yellow, red) indicating pressure levels and a “USE NO OIL” warning. The scale can measure up to 4000 psi and approximately 250 kgf/cm².

Flowmeter: The transparent tube-shaped flowmeter located on the side of the regulator is used to adjust the flow rate (liters/minute) of oxygen delivered to the patient. Its measurement lines are visible.

Humidifier Chamber: This green-colored component humidifies the oxygen before it reaches the patient. The hose connection tip appears intact.

Label and Warning Information

There are some prominent labels and writings on the regulator. This information is listed below:

  • Red Label Warning: The red circular label on the regulator body states “USE NO OIL / UMDER 14700Kpa 150 Kg/cm²”. This is an important safety warning indicating that the device should not come into contact with oil and should be used under the specified pressure.
  • Writings on the Manometer: The manometer dial also features a “USE NO OIL” warning.

No label containing specific identification information such as the product’s serial number, lot number, REF code, or manufacturing year could be identified in the visuals.

Potential Failure Risk and Assessment

No directly fault-causing conditions such as severe visible damage, rust, or excessive wear on critical parts (valve, connection points, etc.) have been detected in the product. Despite being used, the device appears to be in good condition. However, as with all medical devices, periodic inspection and maintenance of such oxygen systems by a qualified technician are crucial for usage safety. Based on visual inspection, there are no obvious defects that would prevent the product from performing its basic functions.