Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 21.04.2026
Report code: 1776780382
Shangyi ZF 700 Surgical Lamp Analysis Report
Device Identification
The image shows a ceiling-mounted surgical lighting system with two heads. This system is a surgical lamp designed for use in operating rooms or intervention rooms.
Brand and Model
The red SHANGYI logo and the blue ZF 700 model number are clearly legible on the outer casing of the left head of the device. Based on this information, the brand of the device is Shangyi and the model is ZF 700.
Authenticity
The print quality of the brand and model labels on the device, the logo design, and the general workmanship details indicate an original product. The labels and the body structure appear to comply with standards.
Usage Areas
This device is used to illuminate the procedure area with high-intensity, shadowless, and daylight-like light during surgical operations and medical interventions. It is suitable for use in all medical areas requiring sterile and technical lighting, such as operating rooms, emergency intervention rooms, outpatient surgery rooms, and veterinary clinics.
Quantity Information
The image shows two lighting heads (one large, one smaller) attached to a single ceiling mounting base, along with articulated arm systems supporting these heads. In total, there is one dual-head surgical lamp system present.
General Condition
The general condition of the device is considered used. Slight dirt and signs of use are visible at the ceiling mounting point and at some joints of the support arms. However, the system maintains its integrity and all parts are in place.
Physical Deformation
No significant fractures, cracks, deep scratches, or dents have been observed on the outer casings or reflective surfaces of the lighting heads. There is slight wear and dirt on the paint of the support arms in some areas. The condition of the light-reflecting facets appears clean.
Mechanical Components
The articulated support arms, the handles that allow the movement of the heads, and the ceiling mounting base appear intact. There are no visible fractures or missing parts in the mechanical components. The sterilizable handles under the heads are in place.
Electronic Components
The internal electronic circuits or bulb systems of the device cannot be analyzed from the image. However, small screen-like structures, which appear to be control panels or indicators, are visible on the rear parts of the heads. No physical damage is observed in these areas.
Accessories
The main parts of the device (base, arms, heads) are complete. The handles located under the heads, which can be removed for sterilization, are attached. There are no external cables, remote controls, or spare part boxes in the image. The blue spiral hose seen on the right has no connection to this device.
Battery Status
No internal or external battery pack belonging to the device is visible in the image. Such devices are usually connected directly to the mains electricity or to a central uninterruptible power supply (UPS).
Label Information
Apart from the brand and model information, a technical data label containing a serial number, lot number, or REF code cannot be clearly identified on the device in the image.
Screen Analysis
There are small digital screens on the rear parts of the lighting heads. However, these screens are turned off, and no text, numbers, or warning messages are visible on them.
Dimensions and Compatibility
Although the exact dimensions of the device cannot be determined from the image, it is understood to be of a size suitable for standard operating room ceiling heights and surgical area lighting needs. The model number ZF 700 generally refers to a technical parameter related to the diameter or lighting capacity of the main head.
Production Year
There is no label or document in the images indicating the production year of the device.
Documents
No documents such as invoices, warranty certificates, or user manuals belonging to the device are visible in the images.
Usage Duration
There is no counter or label in the image showing the total operating hours of the device.
Existing Fault
There is no clear evidence of a fault (broken part, severed cable, etc.) that would prevent the device from operating in the images. The device appears physically intact.
Potential Fault Risk
The general condition of the device is good. Except for slight dirt and signs of use at the joints of the articulated arms and the ceiling mounting base, no serious wear, rust, or cable damage has been observed. This indicates that the mechanical and physical structure of the device is sound and the risk of a potential fault is low.