Ready For Sale
Secondhand Ottobock C-LEG Compact Microprocessor Prosthetic Knee Joint
Price: USD$ 1.200,00Yaklaşık: 51.600,00 TL
Ready For Sale
Ask a Question
Payment
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
Shipping
Standard Shipping Conditions
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
Buyer and Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer Outside of Turkiye, Seller in Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer in Turkiye, Seller Outside Turkiye
- Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
- Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.
Buyer and Seller Outside Turkiye
- Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
- Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 26.09.2025
Otto Bock C-LEG compact Prosthetic Knee Joint Analysis Report
Overview and Product Description
The product shown in the visuals is a microprocessor-controlled prosthetic knee joint designed for above-knee (transfemoral) amputee patients. The product is a medical device component used to provide mobility and safety.
Brand Model and Originality
The product’s brand has been identified as Otto Bock, with the logo and text clearly visible on it. The model name has been confirmed by the C-LEG compact text located on the side surface of the device. Detailed labels, serial number, and CE conformity mark on the device indicate that the product is original.
Physical Condition and Deformation
The general condition of the product is assessed as used. Cosmetically, there are wear marks due to usage. Physical deformations are as follows:
- The metallic grey body of the device has small scratches and light scuff marks in various places.
- A few small dents have been observed punctually.
- No cracks, breaks, or major damage that would affect its structural integrity are visible.
Technical Details and Label Information
Important technical information is present on the device’s labels. This information clearly states the product’s usage limits and origin.
- Maximum Load Capacity: Stated as “MAX. 100 kg” on the label. Furthermore, posture adjustment points for 165 lbs, 220 lbs, 75 kg, and 100 kg are indicated.
- Place of Manufacture: The phrase “MADE IN AUSTRIA” indicates that the product was manufactured in Austria.
- Serial Number: The serial number starting with “SN 201138…” is partially legible on the label.
- Other Codes: Additional technical codes such as “2H92=110” and “15 Nm” are present on the label.
- Certification: The device carries a CE conformity mark.
Mechanical and Electronic Components
As can be understood from the visuals, the mechanical joint structure located at the top part of the device appears solid and functional. No deformation or missing parts have been observed in the adjustment screws and connection points. Due to the device being microprocessor-controlled, it is known to house an electronic system. There is a port on the outer casing, which is presumed to be used for charging or data transfer.
Accessories and Battery
Apart from the device itself, no accessories such as a charging adapter, remote control, or connection cable are present in the visuals. The microprocessor-controlled system draws its power from an internal battery, however, there is no visual information regarding the current health status or charge level of this battery.
Potential Risk Assessment
The product has a normal level of cosmetic imperfections due to being used. However, these scratches and small dents are not severe enough to pose a risk to the device’s structural integrity or functionality. No signs of malfunction have been observed in the mechanical parts. The device appears to be in a solid and functional condition as per its current state.