Secondhand Respirox SZ-T 10L/min Oxygen Concentrator

, , , ,

Price: USD$ 600,00 Approx: 27.000,00 TL

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 29.01.2026

RespiroX SZ-T Oxygen Concentrator Analysis Report

Device Identification

The visual depicts an electrical medical device falling under the category of home medical support equipment. The written labels on the device (“Oxygen Concentrator”) and its structural features (humidifier cup, flow meter tube) clearly indicate that this device is an oxygen concentrator. Furthermore, the outlet ports on the device suggest it possesses functional features not only for oxygen production but also for drug administration.

Brand and Model Information

As a result of the visual inspection conducted on the product, the following identification details have been determined:

  • Brand: RespiroX (Clearly indicated on the front panel with a blue and red logo).
  • Model: SZ-T (Coded directly beneath the brand logo).
  • Device Type: Oxygen Concentrator (The inscription “OXYGEN CONCENTRATOR” is located on the front face).

The branding and labeling on the device are of professional print quality, not appearing as a subsequently added sticker.

Originality and General Structure

Upon examining the product’s outer casing, logo, panel arrangement, and fonts used, it is assessed that the device originates from an industrial production line and is an original RespiroX product. The device features a white, vertical tower-type design.

Physical Condition and Cosmetic Examination

The device’s external cosmetic condition generally appears clean and robust:

  • Casing: No noticeable yellowing, cracks, or major dents have been detected on the white plastic outer casing within the visual angle. The device’s stance is symmetrical, and its integrity is preserved.
  • Surface: There are no deep scratches or prominent heavy stains on the front panel. Possible superficial marks due to use are too minimal to be discerned from the photograph or are non-existent.
  • Control Panel: The screen bezel and keypad area are clean. No significant fading or wear on the plastic buttons is apparent in the visual.

Technical Components and Accessories

The technical equipment identifiable from the visual includes the following:

  • Humidifier Cup: A water reservoir is located in the central part of the device, behind a transparent cover. The reservoir’s black cap and internal connecting tube are in place.
  • Flowmeter: On the right side of the device, there is a vertical transparent tube showing the oxygen flow rate and containing a level ball. It is identified with the label “Flowmeter.” An adjustable flow knob (regulator) is visible on it.
  • Display: A digital LCD screen is located on the upper panel, on the left side. As the device is off, the screen content cannot be analyzed.
  • Oxygen Outlet: On the left side, at the top, there is a main oxygen output port with a metal tip labeled “Oxygen outlet.”
  • Nebulizer Outlet: On the left side, below the oxygen outlet, there is a second outlet labeled “Nebulizing interface” and covered with a threaded metal cap. This feature indicates that the device also has a nebulizer (vapor therapy) function.
  • Power Switch: In the top right corner, there is an I/0 position on/off switch labeled “POWER.”
  • Cables: A black power cable is visible emerging from the left side of the device. There is no visible break or damage in the cable’s insulation.

Areas of Use

The RespiroX SZ-T model is a device that separates nitrogen from ambient air and delivers high-purity oxygen to the patient. Its primary areas of use are:

  • Used for oxygen therapy at home or in clinical settings for patients suffering from COPD, asthma, and respiratory failure.
  • Thanks to its “Nebulizing interface” feature, it can also be used for administering liquid medications to the patient by vaporization (aerosolization).

Current and Potential Risk Assessment

The risk analysis based on visual evidence is as follows:

  • Mechanical: No broken or missing parts were observed in the device’s casing or visible moving components (on/off button, flow adjustment knob).
  • Hygiene: The humidifier cup (water reservoir) is the most critical part in use. While the reservoir is in place in the visual, sterilization or replacement before use is recommended for hygiene purposes.
  • Electronic: Although the device appears to be plugged in (based on the cable extension), as the screen is off and indicator lights are not illuminated, the functionality of the electronic components, the pixel status of the LCD screen, or the operational status of the sensors cannot be verified through the visual.
  • Missing Accessories: The visual focuses on the device itself; a nasal cannula or oxygen mask, which would deliver oxygen to the patient, is not present in the visual.

Quantity Information

The visual shows 1 (one) main unit of the RespiroX SZ-T Oxygen Concentrator and its integrated/connected components (humidifier cup, power cable).